Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 181

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Contrast-Enhanced Spectral Mammography in Women With Intermediate Breast Cancer Risk and Dense Breasts

Sorin, Vera, Yagil, Yael, Yosepovich, Ady, Shalmon, Anat, Gotlieb, Michael, Neiman, Osnat Halshtok, Sklair-Levy, Miri · 2018 · American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of this study was to compare the diagnostic performance of contrast-enhanced spectral mammography (CESM) and ultrasound with that of standard digital mammography for breast cancer screening of women at intermediate risk who have dense breasts. MATERIALS AND METHODS: In a retrospective cohort of 611 consecutively registered women who underwent screening CESM from 2012 to 2017, BI-RADS scores of the screening modalities were compared with actual disease status, assessed by histopathologic analysis or imaging follow-up. Sensitivity, specificity, and positive and negative predictive values were calculated. RESULTS: Among the 611 women included, 48.3% (295/611) had family or personal history of breast cancer, the BI-RADS breast density score was C or D in 93.1% (569/611). The mean follow-up period was 20 months. Mammography depicted 11 of 21 malignancies, sensitivity of 52.4%, specificity of 90.5% (534/590), positive predictive value of 16.4% (11/67), and negative predictive value of 98.2% (534/544). CESM depicted 19 of 21 malignancies, sensitivity of 90.5%, specificity of 76.1% (449/590), positive predictive value of 11.9% (19/160), and negative predictive value of 99.6% (449/451). Differences in sensitivity (p = 0.008) and specificity (p < 0.001) were statistically significant. Adjunct ultrasound revealed 73 additional suspicious findings; all were false-positive. In 39 women MRI was needed to assess screening abnormalities; two MRI-guided biopsies were performed and yielded one cancer. The incremental cancer detection rate of CESM was 13.1/1000 women (95% CI, 6.1-20.1). Of eight cancers seen only with CESM, seven were invasive (mean size, 9 mm; two of four cancers lymph-node positive). CONCLUSION: CESM was significantly more sensitive than standard digital mammography for detecting breast cancer in this screening population. No added benefit was found in the performance of ultrasound as an adjunct to CESM screens with negative results. CESM may be a valuable supplemental screening modality for women at intermediate risk who have dense breasts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.17.19355

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 181

Metadata

Authors
Sorin, V., Yagil, Y., Yosepovich, A., Shalmon, A., Gotlieb, M., Neiman, O. H., & Sklair-Levy, M.
Venue
American Journal of Roentgenology
Published
2018-11
Volume
211
Issue
5
Pages
W267-W274
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2891717422
Cited by
181
References
1
FWCI
9.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.