Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 381

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Differentiation of necrotizing fasciitis and cellulitis using MR imaging.

Schmid, M R, Kossmann, T, Duewell, S · 1998 · American Journal of Roentgenology

Abstract

OBJECTIVE: This study was performed to evaluate the diagnostic value of MR imaging in differentiating necrotizing fasciitis from cellulitis. MATERIALS AND METHODS: Spin-echo T1-weighted, T2-weighted, and contrast-enhanced T1-weighted spin-echo sequences were performed in 15 patients with clinically suspected necrotizing fasciitis. In two other patients, only unenhanced imaging was performed. The MR imaging results were correlated with the surgical findings in 11 cases, with autopsy in one case, and with the clinical outcome in five cases. RESULTS: Cellulitis was diagnosed when subcutaneous thickening with fluid collections was revealed on T2-weighted images and when subcutaneous tissue or superficial fascia or both showed contrast enhancement. For the diagnosis of necrotizing fasciitis, imaging revealed additional involvement of deep fasciae with fluid collections, thickening, and enhancement after contrast administration. According to these criteria, we found 11 cases of necrotizing fasciitis and six of cellulitis. MR imaging identified all 11 cases of necrotizing fasciitis correctly when compared with the surgical findings. One false-positive case of cellulitis was overstaged and was thought to be necrotizing fasciitis. Contrast-enhanced T1-weighted sequences delineated abscesses and areas of necrosis more clearly than T2-weighted sequences did, but showed no additional lesions. CONCLUSION: When no deep fascial involvement is revealed with MR imaging, necrotizing fasciitis can be excluded. However, because its sensitivity exceeds its specificity, MR imaging tends to overestimate the extent of deep fascial involvement. Therefore, the therapeutic regimen should be based on a combination of clinical findings and MR imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.170.3.9490940

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 381

Metadata

Authors
Schmid, M. R., Kossmann, T., & Duewell, S.
Venue
American Journal of Roentgenology
Published
1998-03
Volume
170
Issue
3
Pages
615-620
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2158486165
Cited by
381
References
6
FWCI
12.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Differentiation of necrotizing fasciitis and cellulitis using MR imaging. https://app.cochat.ai/papers/10.2214/ajr.170.3.9490940
The paper
Schmid, M. R., Kossmann, T., & Duewell, S. (1998). Differentiation of necrotizing fasciitis and cellulitis using MR imaging. American Journal of Roentgenology. https://doi.org/10.2214/ajr.170.3.9490940

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.