Hepatocellular carcinoma in North America: a multiinstitutional study of appearance on T1-weighted, T2-weighted, and serial gadolinium-enhanced gradient-echo images.
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of this study was to define the common appearances of hepatocellular carcinoma (HCC) in patients in North America by analyzing T1-weighted, T2-weighted, and serial gadolinium-enhanced gradient-echo images interpreted by radiologists at multiple institutions in North America. MATERIALS AND METHODS: One hundred thirteen consecutive patients with HCC from eight institutions were included in this retrospective case series. Inclusion criteria included MR imaging examinations performed on 1.5-T MR imagers using T1-weighted breath-hold spoiled gradient-echo images, T2-weighted images, and serial gadolinium-enhanced spoiled gradient-echo images. Diagnosis was established by histology in all patients. Images were analyzed retrospectively for lesion count, lesion diameter as less than or equal to 1.5 cm and greater than 1.5 cm, and signal intensity, by individual experienced radiologists at each institution. RESULTS: We found 354 HCC lesions in the 113 patients. Tumors were solitary in 63 patients, multifocal in 45 patients, and diffuse in five patients. Lesion appearance on combined T1-weighted, T2-weighted, and immediate gadolinium-enhanced spoiled gradient-echo images was as follows: 102 lesions (29%) were hypointense on T1-weighted images, were hyperintense on T2-weighted images, and exhibited diffuse heterogeneous enhancement; 52 lesions (15%) were isointense on both T1- and T2-weighted images and exhibited diffuse homogeneous enhancement (all of these lesions measured < or = 1.5 cm in diameter); 50 lesions (14%) were hypointense on T1-weighted images, were hyperintense on T2-weighted images, and exhibited diffuse homogeneous enhancement; 33 lesions (9%) were hypointense on T1-weighted images, were hyperintense on T2-weighted images, and exhibited predominantly peripheral rim enhancement; and 27 lesions (8%) were hypointense on T1-weighted images, were isointense on T2-weighted images, and exhibited diffuse homogeneous enhancement. The remaining 90 lesions showed less common patterns. The appearance of HCCs greater than 1.5 cm and of HCCs less than or equal to 1.5 cm was significantly different (p = .001). The appearance of histologically proven HCCs is separately described. CONCLUSION: The combination of hypointensity on T1-weighted images, hyperintensity on T2-weighted images, and diffuse heterogeneous enhancement was the most common appearance of HCC on MR images in a multiinstitutional patient population in North America. Small HCCs measuring less than or equal to 1.5 cm were frequently isointense on both T1-weighted and T2-weighted images and may be detected on immediate gadolinium-enhanced images only as diffuse homogeneously enhancing lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hepatocellular carcinoma: correlation of MR imaging and histopathologic findings.
Kadoya, M., Matsui, O., Takashima, T., & Nonomura, A. (1992) · Radiology · doi:10.1148/radiology.183.3.1316622 · Cited by 280 · cited 3×
“Prior reports [2, 3, 10, 28] have described the presence of tumor capsules in 54-90% of HCCs in Asian populations and in 12-42% of patients with HCC in a nonAsian population.”
BackgroundYamashita, Y., Mitsuzaki, K., Yi, T., Ogata, I., Nishiharu, T., Urata, J., & Takahashi, M. (1996) · Radiology · doi:10.1148/radiology.200.1.8657948 · Cited by 272
Earls, J. P., Theise, N. D., Weinreb, J. C., DeCorato, D. R., Krinsky, G. A., Rofsky, N. M., Mizrachi, H., & Teperman, L. W. (1996) · Radiology · doi:10.1148/radiology.201.1.8816545 · Cited by 176
Hepatic adenoma: MR findings in 51 pathologically proved lesions.
Arrivé, L., Fléjou, J., Vilgrain, V., Belghiti, J., Najmark, D., Zins, M., Menu, Y., Tubiana, J. M., & Nahum, H. (1994) · Radiology · doi:10.1148/radiology.193.2.7972769 · Cited by 146
Larson, R. E., Semelka, R. C., Bagley, A. S., Molina, P. L., Brown, E. D., & Lee, J. K. (1994) · Radiology · doi:10.1148/radiology.192.2.8029403 · Cited by 139
Self-citationMITCHELL, D. G., KIM, I., CHANG, T. S., VINITSKI, S., SAPONARO, S. A., EHRLICH, S. M., RIFKIN, M. D., & RUBIN, R. (1991) · Investigative Radiology · doi:10.1097/00004424-199112000-00002 · Cited by 131
Self-citationMR imaging of hepatocellular carcinoma at 1.5 Tesla
Rosenthal, R. E., & Davis, P. L. (1992) · Abdominal Imaging · doi:10.1007/bf01888508 · Cited by 9
Cited by
Krinsky, G. A., Lee, V. S., Theise, N. D., Weinreb, J. C., Rofsky, N. M., Diflo, T., & Teperman, L. W. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma40445 · Cited by 332
Rode, A., Bancel, B., Douek, P., Chevallier, M., Vilgrain, V., Picaud, G., Henry, L., Berger, F., Bizollon, T., Gaudin, J.-L., et al. (2001) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200105000-00001 · Cited by 292
Vandecaveye, V., De Keyzer, F., Verslype, C., Op de Beeck, K., Komuta, M., Topal, B., Roebben, I., Bielen, D., Roskams, T., Nevens, F., et al. (2009) · European Radiology · doi:10.1007/s00330-009-1431-5 · Cited by 181
“arterial enhancement, wash-out of contrast agent during venous phase and rim enhancement [15].”
BackgroundGuo, P., Wang, P., Zhou, J., Jiang, S., & Patel, V. M. (2021) · 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr46437.2021.00245 · Cited by 193
Implications of SENSE MR in routine clinical practice
van den Brink, J. S., Watanabe, Y., Kuhl, C. K., Chung, T., Muthupillai, R., Van Cauteren, M., Yamada, K., Dymarkowski, S., Bogaert, J., Maki, J. H., et al. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00333-9 · Cited by 160
Metadata
- Authors
- Kelekis, N. L., Semelka, R. C., Worawattanakul, S., de Lange, E. E., Ascher, S. M., Ahn, I. O., Reinhold, C., Remer, E. M., Brown, J. J., Bis, K. G., Woosley, J. T., & Mitchell, D. G.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1998-04
- Volume
- 170
- Issue
- 4
- Pages
- 1005-1013
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2060952848
- Cited by
- 161
- References
- 7
- FWCI
- 4.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.