Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 181

The DOI matches its Crossref record.

Diagnostic criteria for fatty infiltration of the liver on contrast-enhanced helical CT.

Jacobs, J E, Birnbaum, B A, Shapiro, M A, Langlotz, C P, Slosman, F, Rubesin, S E, Horii, S C · 1998 · American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of the study was to develop quantitative and qualitative criteria for diagnosing fatty liver on contrast-enhanced helical CT. SUBJECTS AND METHODS: Differential liver-spleen attenuation was evaluated between 80 and 120 sec after injection in 76 patients who underwent contrast-enhanced helical CT. Unenhanced CT images had earlier established fatty liver when the liver minus spleen attenuation difference was less than or equal to -10 H (n = 18). Four observers who had not seen the unenhanced images used contrast-enhanced CT images to assess the presence of fatty liver on a five-point Likert scale, the presence of geographic areas spared from fatty infiltration, and the relative liver-spleen attenuation. The diagnostic accuracies of various imaging criteria were compared using McNemar's chi-square test (for sensitivity and specificity) and analysis of receiver operating characteristic curves. RESULTS: Sensitivity, specificity, and receiver operating characteristic curve areas for observers' qualitative judgments were 54%, 95%, and .91, respectively; for quantitative differential liver-spleen attenuation (80-100 sec; -20.5 H discriminatory value), the values were 86%, 87%, and .94, respectively; and for quantitative differential liver-spleen attenuation (101-120 sec; -18.5 H discriminatory value), the values were 93%, 93%, and .98, respectively. Differential liver-spleen attenuation was time-dependent; overlap was noted between healthy subjects and patients with fatty liver. Qualitatively, geographic sparing was highly specific (94%) for fatty liver, whereas liver attenuation greater than or equal to spleen attenuation excluded fatty liver in all but one case. CONCLUSION: Although quantitative and qualitative criteria for diagnosing fatty liver on helical CT can be determined, they are protocol-specific. Limited unenhanced hepatic CT remains the optimal technique for detection of fatty infiltration of the liver.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.171.3.9725292

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 181

Metadata

Authors
Jacobs, J. E., Birnbaum, B. A., Shapiro, M. A., Langlotz, C. P., Slosman, F., Rubesin, S. E., & Horii, S. C.
Venue
American Journal of Roentgenology
Published
1998-09
Volume
171
Issue
3
Pages
659-664
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2081405075
Cited by
181
References
0
FWCI
0.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic criteria for fatty infiltration of the liver on contrast-enhanced helical CT. https://app.cochat.ai/papers/10.2214/ajr.171.3.9725292
The paper
Jacobs, J. E., Birnbaum, B. A., Shapiro, M. A., Langlotz, C. P., Slosman, F., Rubesin, S. E., & Horii, S. C. (1998). Diagnostic criteria for fatty infiltration of the liver on contrast-enhanced helical CT. American Journal of Roentgenology. https://doi.org/10.2214/ajr.171.3.9725292

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.