Continuous Speech Recognition in MR Imaging Reporting: Advantages, Disadvantages, and Impact
The DOI matches its Crossref record.
Abstract
OBJECTIVE: Our objective was to describe our experience with a commercially available continuous speech recognition system, highlighting the advantages, disadvantages, and costs compared with those of conventional transcription for MR imaging reports. MATERIALS AND METHODS: Data from 5072 reports generated in our MR imaging section during a 9-month period after the implementation of a commercial continuous speech recognition system were compared with 4552 reports produced during the same period 1 year earlier. Information pertaining to the use of continuous speech recognition, report turnaround time, word recognition rate, report appearance, and equipment costs was collected. RESULTS: After its system installation, continuous speech recognition was used to dictate 81.8% of all reports. The mean report turnaround time decreased from 87.8 to 43.6 hr, and report availability at 24 hr increased from 10.5% to 62.5%. The system was found to have an average word recognition accuracy of 92.7% for spontaneous dictation. Mean report length declined from 95 to 60 words, with an increase in spacing errors from 0.3 to 8.0 per 1000 words and a decrease in spelling errors from 3.0 to 0.8 per 1000 words. Initial hardware and software costs were approximately $10,000, compared with a yearly cost of $12,000 for human transcription. CONCLUSION: Although the technology is still evolving and was evaluated in its earliest implementation stages, continuous speech recognition nonetheless markedly improved report turnaround time and proved cost-effective.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Costs and benefits of health information technology.
Shekelle, P. G., Morton, S. C., & Keeler, E. B. (2006) · doi:10.23970/ahrqepcerta132 · Cited by 501
Speech recognition for clinical documentation from 1990 to 2018: a systematic review
Blackley, S. V., Huynh, J., Wang, L., Korach, Z., & Zhou, L. (2019) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocy179 · Cited by 97
Zhou, L., Blackley, S. V., Kowalski, L., Doan, R., Acker, W. W., Landman, A. B., Kontrient, E., Mack, D., Meteer, M., Bates, D. W., et al. (2018) · JAMA Network Open · doi:10.1001/jamanetworkopen.2018.0530 · Cited by 94
Metadata
- Authors
- Ramaswamy, M. R., Chaljub, G., Esch, O., Fanning, D. D., & vanSonnenberg, E.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2000-03
- Volume
- 174
- Issue
- 3
- Pages
- 617-622
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2053115136
- Cited by
- 73
- References
- 0
- FWCI
- 11.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Speech Recognition in MR Imaging Reporting: Advantages, Disadvantages, and Impact. https://app.cochat.ai/papers/10.2214/ajr.174.3.1740617
- The paper
- Ramaswamy, M. R., Chaljub, G., Esch, O., Fanning, D. D., & vanSonnenberg, E. (2000). Continuous Speech Recognition in MR Imaging Reporting: Advantages, Disadvantages, and Impact. American Journal of Roentgenology. https://doi.org/10.2214/ajr.174.3.1740617
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.