CoChat

Impact of Multidetector CT on Donor Selection and Surgical Planning Before Living Adult Right Lobe Liver Transplantation

Kamel, Ihab R., Kruskal, Jonathan B., Pomfret, Elizabeth A., Keogan, Mary T., Warmbrand, Gizele, Raptopoulos, Vassilios · 2001 · American Journal of Roentgenology
Cited by 224

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: This study was performed to document the impact of multidetector multiphase CT in facilitating patient selection and surgical planning in potential donors being evaluated for living adult right lobe liver transplantation. SUBJECTS AND METHODS: Forty consecutive potential donors were included in the study. There were 26 men and 14 women, (age range, 18-57 years; mean, 37 years) We performed CT using a multidetector scanner, after IV injection of 180 mL of contrast material at 5 mL/sec. Arterial phase images were acquired at 18 sec (collimation, 1.25 mm; table speed, 7.5) and portal phase images, at 60 sec (collimation, 2.5 mm; table speed, 15). Postprocessing was performed on a commercially available workstation. CT data included dual-energy assessment of liver parenchyma for fatty infiltration; depiction of arterial, portal venous, and hepatic venous anatomy and identification of important vascular variants; and determination of total and lobar liver volume. RESULTS: Of the 40 potential liver donors evaluated, 15 patients (37.5%) were excluded on the basis of CT findings, with most exclusions a result of portal vein anomalies (n = 8). Fatty infiltration resulted in four exclusions (10%), and small liver volume resulted in three exclusions (7.5%). CONCLUSION: Multidetector multiphase CT provided comprehensive parenchymal, vascular, and volumetric preoperative evaluation of potential donors undergoing living adult right lobe liver transplantation. This information had a major impact on patient selection because it was used to stratify patients. It allowed the surgeons to plan their surgical approach, and this planning may reduce postoperative complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.176.1.1760193

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

Metadata

Authors
Kamel, I. R., Kruskal, J. B., Pomfret, E. A., Keogan, M. T., Warmbrand, G., & Raptopoulos, V.
Venue
American Journal of Roentgenology
Published
2001-01
Volume
176
Issue
1
Pages
193-200
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2140142039
Cited by
224
References
13
FWCI
15.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.