Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 216

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Comparison of Permeability in High-Grade and Low-Grade Brain Tumors Using Dynamic Susceptibility Contrast MR Imaging

Provenzale, James M., Wang, Gin R., Brenner, Thomas, Petrella, Jeffrey R., Sorensen, A. Gregory · 2002 · American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of this study was to compare permeability measurements in high-grade and low-grade glial neoplasms using a T2(*)-weighted method. Our hypothesis was that permeability measurements using a T2(*)-weighted technique would show permeability in high-grade neoplasms to be higher than that in low-grade neoplasms. MATERIALS AND METHODS: Twelve patients with biopsy-proven high-grade neoplasms and 10 patients with biopsy-proven low-grade neoplasms underwent dynamic susceptibility contrast MR perfusion imaging (TR/TE, 1500/80) after bolus infusion of 0.2 mmol/kg of MR contrast material. Color-coded permeability-weighted maps were created using a model that weights relative contributions to signal intensity from intravascular T2(*) effects and extravascular T1 effects from blood-brain barrier permeability. Two measures of permeability were performed: mean value of highest permeability found on three images through the tumor (mean regional value) and highest value found at any region of interest in the tumor (single area of maximum permeability). Depending on the normality of the data sets, we used the Wilcoxon's rank sum test or the two-tailed Student's t test for statistical analysis. RESULTS: For low-grade tumors, the range was 0.006-0.041, and the median of the mean regional value for each image was 0.017. For high-grade tumors, the range was 0.005-0.092, and the median of the mean regional value was 0.035 (p = 0.025). For low-grade tumors, the range was 0.008-0.045, and the mean of the single area of maximum values was 0.02. For high-grade tumors, the range was 0.007-0.136, and the mean of the single area of maximum values was 0.054 (p = 0.018). CONCLUSION: Permeability values for high-grade tumors obtained using a T2(*)-weighted method were significantly greater than those for low-grade tumors and are consistent with previous studies reporting results using T1-weighted methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.178.3.1780711

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 216

Metadata

Authors
Provenzale, J. M., Wang, G. R., Brenner, T., Petrella, J. R., & Sorensen, A. G.
Venue
American Journal of Roentgenology
Published
2002-03
Volume
178
Issue
3
Pages
711-716
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2056077646
Cited by
216
References
1
FWCI
5.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Permeability in High-Grade and Low-Grade Brain Tumors Using Dynamic Susceptibility Contrast MR Imaging. https://app.cochat.ai/papers/10.2214/ajr.178.3.1780711
The paper
Provenzale, J. M., Wang, G. R., Brenner, T., Petrella, J. R., & Sorensen, A. G. (2002). Comparison of Permeability in High-Grade and Low-Grade Brain Tumors Using Dynamic Susceptibility Contrast MR Imaging. American Journal of Roentgenology. https://doi.org/10.2214/ajr.178.3.1780711

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.