Detection and Characterization of Intracardiac Thrombi on MR Imaging
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The aim of our study was to compare the diagnostic accuracy achieved using different MR techniques with the diagnostic accuracy achieved using transthoracic and transesophageal echocardiography to detect intracardiac thrombi. MATERIALS AND METHODS: Twenty-four patients with known or suspected intracardiac thrombi were examined using MR imaging and echocardiography. All MR examinations were performed on a 1.5-T MR scanner using dark-blood-prepared half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences, fast imaging steady-state free precession (trueFISP) cine sequences, and inversion recovery gradient-echo fast low-angle-shot (inversion recovery turbo FLASH) sequences after injection of 0.2 mmol/kg of gadolinium diethylene triamine pentaacetic acid. RESULTS: MR imaging and echocardiography revealed 12 thrombi-two in the right atrium, one in the right ventricle, three in the left atrium, and six in the left ventricle. Compared with echocardiography, MR imaging revealed three additional thrombi in the left ventricle; these thrombi were confirmed at surgery. All 15 thrombi appeared as filling defects on early contrast-enhanced inversion recovery turbo FLASH MR images. Only seven thrombi were detected on HASTE images, and 10 thrombi were seen on trueFISP images. Four thrombi showed enhancement 10-20 min after contrast material injection and were characterized as organized clots. CONCLUSION: Contrast-enhanced inversion recovery turbo FLASH sequences were superior to dark-blood-prepared HASTE and trueFISP cine MR images in revealing intracardiac thrombi. Compared with transthoracic echocardiography, MR imaging was more sensitive for the detection of left ventricular thrombi. The characterization of thrombi may be used to predict the risk of embolism, which is higher for subacute clots than for organized thrombi.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Improved MR Imaging Technique for the Visualization of Myocardial Infarction
Simonetti, O. P., Kim, R. J., Fieno, D. S., Hillenbrand, H. B., Wu, E., Bundy, J. M., Finn, J. P., & Judd, R. M. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja50215 · Cited by 1,358
The Lausanne Stroke Registry: analysis of 1,000 consecutive patients with first stroke.
Bogousslavsky, J., Van Melle, G., & Regli, F. (1988) · Stroke · doi:10.1161/01.str.19.9.1083 · Cited by 1,350
Chartier, L., Béra, J., Delomez, M., Asseman, P., Beregi, J.-P., Bauchart, J.-J., Warembourg, H., & Théry, C. (1999) · Circulation · doi:10.1161/01.cir.99.21.2779 · Cited by 476
Barkhausen, J., Ruehm, S. G., Goyen, M., Buck, T., Laub, G., & Debatin, J. F. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap12264 · Cited by 380
Self-citationCasazza, F., Bongarzoni, A., Centonze, F., & Morpurgo, M. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00162-8 · Cited by 203
Transesophageal Echocardiography
Daniel, W. G., & Mügge, A. (1995) · New England Journal of Medicine · doi:10.1056/nejm199505113321906 · Cited by 178
Paydarfar, D., Krieger, D. W., Dib, N., Blair, R. H., Pastore, J. O., Stetz, J. J., & Symes, J. F. (2001) · Cardiology · doi:10.1159/000047342 · Cited by 125
Dynamic 3D MR angiography of the pulmonary arteries in under four seconds
Goyen, M., Laub, G. A., Ladd, M. E., Debatin, J. F., Barkhausen, J., Truemmler, K., Bosk, S., & Ruehm, S. G. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1053 · Cited by 106
Self-citationVentricular thrombosis and systemic embolism in bodybuilders: etiology and management
McCarthy, K., Tang, A. T. M., Dalrymple-Hay, M. J. R., & Haw, M. P. (2000) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(00)01572-1 · Cited by 56
Palazzuoli, A., Ricci, D., Lenzi, C., Lenzi, J., & Palazzuoli, V. (2000) · Neurological Sciences · doi:10.1007/s100720070076 · Cited by 38
Krumholz, H. M., Howes, C., Murillo, J. E., Vaccarino, V., Radford, M. J., & Ellerbeck, E. F. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00299-3 · Cited by 26
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.013 · Cited by 924
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318214876d · Cited by 859
Writing Committee Members, Fuster, V., Ryden, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., et al. (2006) · Europace · doi:10.1093/europace/eul097 · Cited by 667
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.018 · Cited by 467
Metadata
- Authors
- Barkhausen, J., Hunold, P., Eggebrecht, H., Schüler, W. O., Sabin, G. V., Erbel, R., & Debatin, J. F.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2002-12
- Volume
- 179
- Issue
- 6
- Pages
- 1539-1544
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2161561297
- Cited by
- 188
- References
- 11
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.