Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 189

The DOI matches its Crossref record.

Improvement in Sensitivity of Screening Mammography with Computer-Aided Detection:A Multiinstitutional Trial

Brem, Rachel F., Baum, Janet, Lechner, Mary, Kaplan, Stuart, Souders, Stuart, Naul, L. Gill, Hoffmeister, Jeff·2003·American Journal of Roentgenology

Abstract

OBJECTIVE: Our study evaluated radiologist detection of breast cancer using a computer-aided detection system. MATERIALS AND METHODS: Three radiologists reviewed 377 screening mammograms interpreted as showing normal or benign findings 9-24 months before cancer diagnosis from 17 of the 18 participating centers. In 313 cases, study radiologists recommended additional mammographic evaluation. In 177 cases, the area warranting additional workup precisely correlated with the subsequently diagnosed cancer. These 177 missed cancers were evaluated with computer-aided detection. The proportion of radiologists identifying the missed cancers was used to determine radiologist sensitivity without computer-aided detection. RESULTS: The study radiologists determined that 123 of the 377 missed cancer cases warranted workup. Therefore, 123 additional cancers cases could have been found. The calculated radiologist sensitivity without computer-aided detection was therefore 75.4% (377 / [377 + 123]). Similarly, using the performance of the system on the missed cancers, we estimated that 80 (65.0%) of these 123 missed cancer cases would have been identified with the use of computer-aided detection. Consequently, the estimated sensitivity of radiologists using computer-aided detection was 91.4% ([377 + 80] / [377 + 123])-resulting in a 21.2% ([91.4% / 75.4%] - 1) increase in radiologist sensitivity with computer-aided detection. CONCLUSION: Use of the computer-aided detection system significantly improved the detection of breast cancer by increasing radiologist sensitivity by 21.2%. Therefore, for every 100,000 women with breast cancer identified without the use of computer-aided detection, an estimated additional 21,200 cancers would be found with the use of computer-aided detection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.181.3.1810687

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 189

Metadata

Authors
Brem, R. F., Baum, J., Lechner, M., Kaplan, S., Souders, S., Naul, L. G., & Hoffmeister, J.
Venue
American Journal of Roentgenology
Published
2003-09
Volume
181
Issue
3
Pages
687-693
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2102018226
Cited by
189
References
0
FWCI
17.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improvement in Sensitivity of Screening Mammography with Computer-Aided Detection:A Multiinstitutional Trial. https://app.cochat.ai/papers/10.2214/ajr.181.3.1810687
The paper
Brem, R. F., Baum, J., Lechner, M., Kaplan, S., Souders, S., Naul, L. G., & Hoffmeister, J. (2003). Improvement in Sensitivity of Screening Mammography with Computer-Aided Detection:A Multiinstitutional Trial. American Journal of Roentgenology. https://doi.org/10.2214/ajr.181.3.1810687

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.