Improvement in Sensitivity of Screening Mammography with Computer-Aided Detection:A Multiinstitutional Trial
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Our study evaluated radiologist detection of breast cancer using a computer-aided detection system. MATERIALS AND METHODS: Three radiologists reviewed 377 screening mammograms interpreted as showing normal or benign findings 9-24 months before cancer diagnosis from 17 of the 18 participating centers. In 313 cases, study radiologists recommended additional mammographic evaluation. In 177 cases, the area warranting additional workup precisely correlated with the subsequently diagnosed cancer. These 177 missed cancers were evaluated with computer-aided detection. The proportion of radiologists identifying the missed cancers was used to determine radiologist sensitivity without computer-aided detection. RESULTS: The study radiologists determined that 123 of the 377 missed cancer cases warranted workup. Therefore, 123 additional cancers cases could have been found. The calculated radiologist sensitivity without computer-aided detection was therefore 75.4% (377 / [377 + 123]). Similarly, using the performance of the system on the missed cancers, we estimated that 80 (65.0%) of these 123 missed cancer cases would have been identified with the use of computer-aided detection. Consequently, the estimated sensitivity of radiologists using computer-aided detection was 91.4% ([377 + 80] / [377 + 123])-resulting in a 21.2% ([91.4% / 75.4%] - 1) increase in radiologist sensitivity with computer-aided detection. CONCLUSION: Use of the computer-aided detection system significantly improved the detection of breast cancer by increasing radiologist sensitivity by 21.2%. Therefore, for every 100,000 women with breast cancer identified without the use of computer-aided detection, an estimated additional 21,200 cancers would be found with the use of computer-aided detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breast imaging reporting and data system (BI-RADS)
Liberman, L., & Menell, J. H. (2002) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(01)00017-3 · Cited by 2,155
Kolb, T. M., Lichy, J., & Newhouse, J. H. (2002) · Radiology · doi:10.1148/radiol.2251011667 · Cited by 1,718 · cited 1×
“The sensitivity of mammography ranges from approximately 70% to 90% [7–14].”
BackgroundBreast Cancer Screening: A Summary of the Evidence for the U.S. Preventive Services Task Force
Humphrey, L. L., Helfand, M., Chan, B. K. S., & Woolf, S. H. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-137-5_part_1-200209030-00012 · Cited by 1,137
Is screening for breast cancer with mammography justifiable?
Gøtzsche, P. C., & Olsen, O. (2000) · The Lancet · doi:10.1016/s0140-6736(99)06065-1 · Cited by 853 · cited 1×
“Although a recent analysis of eight randomized breast cancer screening trials questions the reduction in mortality from screening with mammography [3] and the Physician Data Query Panel sponsored by the National Cancer Institute concurs with this uncertainty [4], other United States and international organizations sti…”
BackgroundAnalysis of cancers missed at screening mammography.
Bird, R. E., Wallace, T. W., & Yankaskas, B. C. (1992) · Radiology · doi:10.1148/radiology.184.3.1509041 · Cited by 820 · cited 3×
“The sensitivity of mammography ranges from approximately 70% to 90% [7–14].”
BackgroundReport of the International Workshop on Screening for Breast Cancer
Fletcher, S. W., Black, W., Harris, R., Rimer, B. K., & Shapiro, S. (1993) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/85.20.1644 · Cited by 792 · cited 1×
“The sensitivity of mammography ranges from approximately 70% to 90% [7–14].”
BackgroundUPDATE OF THE SWEDISH TWO-COUNTY PROGRAM OF MAMMOGRAPHIC SCREENING FOR BREAST CANCER
Tabàr, L., Fagerberg, G., Duffy, S. W., Day, N. E., Gad, A., & Gröntoft, O. (1992) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(22)02494-0 · Cited by 731 · cited 3×
“This may explain why breast cancer detection rates are higher with double interpretation [15–26].”
BackgroundThe Lifetime Risk of Developing Breast Cancer
Feuer, E. J., Wun, L.-M., Boring, C. C., Flanders, W. D., Timmel, M. J., & Tong, T. (1993) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/85.11.892 · Cited by 639 · cited 1×
“The lifetime risk of a woman developing this disease has been established as one in eight [2].”
BackgroundPotential Contribution of Computer-aided Detection to the Sensitivity of Screening Mammography
Warren Burhenne, L. J., Wood, S. A., D'Orsi, C. J., Feig, S. A., Kopans, D. B., O'Shaughnessy, K. F., Sickles, E. A., Tabar, L., Vyborny, C. J., & Castellino, R. A. (2000) · Radiology · doi:10.1148/radiology.215.2.r00ma15554 · Cited by 554 · cited 3×
“where N found is the number of potentially missed cancer cases with subsequent screening mammograms that led to the diagnosis of cancer obtained 9–24 months after the potentially missed cancer mammogram [34].”
BackgroundMethodInfluentialBirdwell, R. L., Ikeda, D. M., O’Shaughnessy, K. F., & Sickles, E. A. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap16192 · Cited by 428
Benefit of independent double reading in a population-based mammography screening program.
Thurfjell, E. L., Lernevall, K. A., & Taube, A. A. (1994) · Radiology · doi:10.1148/radiology.191.1.8134580 · Cited by 406 · cited 3×
“This may explain why breast cancer detection rates are higher with double interpretation [15–26].”
BackgroundBreast cancer missed by mammography
Martin, J., Moskowitz, M., & Milbrath (1979) · American Journal of Roentgenology · doi:10.2214/ajr.132.5.737 · Cited by 246 · cited 1×
“Clinical studies have shown that 30–70% of breast cancers diagnosed at screening mammography are visible in retrospect on prior examinations and that detection errors are responsible for approximately half of missed breast cancers, with interpretation errors accounting for the other half [10, 27–33].”
BackgroundKerlikowske, K., Carney, P. A., Geller, B., Mandelson, M. T., Taplin, S. H., Malvin, K., Ernster, V., Urban, N., Cutter, G., Rosenberg, R., et al. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-11-200012050-00009 · Cited by 233 · cited 1×
“The sensitivity of mammography ranges from approximately 70% to 90% [7–14].”
BackgroundHarvey, J. A., Fajardo, L. L., & Innis, C. A. (1993) · American Journal of Roentgenology · doi:10.2214/ajr.161.6.8249720 · Cited by 195
The efficacy of double reading mammograms in breast screening
Anderson, E. D. C., Muir, B. B., Walsh, J. S., & Kirkpatrick, A. E. (1994) · Clinical Radiology · doi:10.1016/s0009-9260(05)81850-1 · Cited by 156 · cited 3×
“This may explain why breast cancer detection rates are higher with double interpretation [15–26].”
BackgroundIkeda, D. M., Andersson, I., Wattsgård, C., Janzon, L., & Linell, F. (1992) · American Journal of Roentgenology · doi:10.2214/ajr.159.2.1632342 · Cited by 151 · cited 1×
“Clinical studies have shown that 30–70% of breast cancers diagnosed at screening mammography are visible in retrospect on prior examinations and that detection errors are responsible for approximately half of missed breast cancers, with interpretation errors accounting for the other half [10, 27–33].”
BackgroundBrown, J., Bryan, S., & Warren, R. M. L. (1996) · BMJ · doi:10.1136/bmj.312.7034.809 · Cited by 132 · cited 3×
“This may explain why breast cancer detection rates are higher with double interpretation [15–26].”
BackgroundCharacteristics of breast carcinomas missed by screening radiologists.
Goergen, S., Evans, J., Cohen, G. P., & MacMillan, J. H. (1997) · Radiology · doi:10.1148/radiology.204.1.9205234 · Cited by 124 · cited 1×
“The sensitivity of mammography ranges from approximately 70% to 90% [7–14].”
BackgroundDouble reading of mammography screening films-one radiologist or two?
Anttinen, I., Pamilo, M., Soiva, M., & Roiha, M. (1993) · Clinical Radiology · doi:10.1016/s0009-9260(05)81111-0 · Cited by 118 · cited 3×
“This may explain why breast cancer detection rates are higher with double interpretation [15–26].”
BackgroundRobertson, C. L. (1993) · Radiology · doi:10.1148/radiology.187.1.8451440 · Cited by 93 · cited 1×
“The sensitivity of mammography ranges from approximately 70% to 90% [7–14].”
BackgroundEffect of human variability on independent double reading in screening mammography
Beam, C. A., Sullivan, D. C., & Layde, P. M. (1996) · Academic Radiology · doi:10.1016/s1076-6332(96)80296-0 · Cited by 90 · cited 3×
“This may explain why breast cancer detection rates are higher with double interpretation [15–26].”
BackgroundWarren, R. M. L., & Duffy, W. (1995) · British Journal of Radiology · doi:10.1259/0007-1285-68-813-958 · Cited by 89 · cited 3×
“This may explain why breast cancer detection rates are higher with double interpretation [15–26].”
BackgroundBrem, R. F., & Schoonjans, J. M. (2001) · Clinical Radiology · doi:10.1053/crad.2000.0592 · Cited by 55 · cited 1×
“In fact, a prior study reported breast cancer detection is improved with the use of computer-aided detection—even when used by experienced mammographers [35].”
BackgroundSelf-citationKopans, D. B. (2000) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(05)70196-2 · Cited by 41
Cited by
Detecting and classifying lesions in mammograms with Deep Learning
Ribli, D., Horváth, A., Unger, Z., Pollner, P., & Csabai, I. (2018) · Scientific Reports · doi:10.1038/s41598-018-22437-z · Cited by 696
“These controversial results indicate that CAD systems need to be improved before radiologists can ultimately benefit from using the technology in everyday practice.”
ResultInfluentialInfluence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, J. J., Taplin, S. H., Carney, P. A., Abraham, L., Sickles, E. A., D'Orsi, C., Berns, E. A., Cutter, G., Hendrick, R. E., Barlow, W. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066099 · Cited by 619
Computer-Aided Detection and Diagnosis of Breast Cancer With Mammography: Recent Advances
Tang, J., Rangayyan, R. M., Xu, J., El Naqa, I., & Yang, Y. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2009441 · Cited by 619
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
Computer-aided detection/diagnosis of breast cancer in mammography and ultrasound: a review
Jalalian, A., Mashohor, S. B. T., Mahmud, H. R., Saripan, M. I. B., Ramli, A. R. B., & Karasfi, B. (2013) · Clinical Imaging · doi:10.1016/j.clinimag.2012.09.024 · Cited by 337
Metadata
- Authors
- Brem, R. F., Baum, J., Lechner, M., Kaplan, S., Souders, S., Naul, L. G., & Hoffmeister, J.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2003-09
- Volume
- 181
- Issue
- 3
- Pages
- 687-693
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2102018226
- Cited by
- 189
- References
- 24
- FWCI
- 17.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.