Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 198

The DOI matches its Crossref record.

MDCT Compared with Digital Subtraction Angiography for Assessment of Lower Extremity Arterial Occlusive Disease: Importance of Reviewing Cross-Sectional Images

Ota, Hideki, Takase, Kei, Igarashi, Kazumasa, Chiba, Yoshihiro, Haga, Kenichi, Saito, Haruo, Takahashi, Shoki · 2004 · American Journal of Roentgenology

Abstract

OBJECTIVE: The aim of our study was to evaluate the efficacy of MDCT angiography in the assessment of lower limb peripheral arterial occlusive disease. MATERIALS AND METHODS: Twenty-four patients (representing 27 cases) with symptomatic lower extremity peripheral arterial occlusive disease underwent both MDCT angiography and digital subtraction angiography of the aortoiliac and lower extremity arteries. For data analysis, the arterial system was divided into 10 segments. Each segment was classified as normal, mildly stenotic, moderately stenotic, severely stenotic, or occluded. In evaluating MDCT angiographic findings, cross-sectional images were mainly observed by scrolling. The diagnostic accuracy of MDCT angiography was determined, using digital subtraction angiography as the standard reference. The extent of calcification in each segment was also assessed on MDCT angiography and was classified as absent, mildly calcified, or severely calcified. RESULTS: Of the 480 segments studied, 470 were assessable on both digital subtraction angiography and MDCT angiography. On digital subtraction angiography, 142 stenoocclusive segments (20 mildly stenotic, 14 moderately stenotic, 25 severely stenotic, and 83 occluded) were detected. With regard to the detection of segments that had more than mild stenosis, the sensitivity, specificity, and accuracy of MDCT angiography were 99.2%, 99.1%, and 99.1%, respectively. In the 421 noncalcified and mildly calcified segments, the sensitivity, specificity, and accuracy of MDCT angiography for the detection of more-than-mild stenosis were 100%, 100%, and 100%, respectively. CONCLUSION: MDCT angiography is a reliable method for evaluating the aortoiliac and lower extremity arteries.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.182.1.1820201

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 198

Metadata

Authors
Ota, H., Takase, K., Igarashi, K., Chiba, Y., Haga, K., Saito, H., & Takahashi, S.
Venue
American Journal of Roentgenology
Published
2004-01
Volume
182
Issue
1
Pages
201-209
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2159746297
Cited by
198
References
0
FWCI
15.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MDCT Compared with Digital Subtraction Angiography for Assessment of Lower Extremity Arterial Occlusive Disease: Importance of Reviewing Cross-Sectional Images. https://app.cochat.ai/papers/10.2214/ajr.182.1.1820201
The paper
Ota, H., Takase, K., Igarashi, K., Chiba, Y., Haga, K., Saito, H., & Takahashi, S. (2004). MDCT Compared with Digital Subtraction Angiography for Assessment of Lower Extremity Arterial Occlusive Disease: Importance of Reviewing Cross-Sectional Images. American Journal of Roentgenology. https://doi.org/10.2214/ajr.182.1.1820201

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.