The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
CT Evaluation of the Response of Gastrointestinal Stromal Tumors After Imatinib Mesylate Treatment: A Quantitative Analysis Correlated with FDG PET Findings
Abstract
OBJECTIVE: We correlated changes in tumor density on CT with changes in glucose metabolism, or the maximum standardized uptake value (SUV(max)), on FDG PET and sought to develop CT imaging criteria that can be used to objectively evaluate tumor response in patients with metastatic gastrointestinal stromal tumors (GISTs) who undergo treatment with imatinib mesylate. MATERIALS AND METHODS: Using the criteria established by the Response Evaluation Criteria in Solid Tumors (RECIST) group, we selected 173 tumors (in 36 patients) for study. Tumor size and density were determined objectively, and overall tumor response (OTR) was evaluated subjectively on CT images. The changes in these parameters before and after treatment were correlated with changes in SUV(max). RESULTS: Significant decreases were seen in both tumor density (mean, 12.3 H [16.5%]; p < 0.0001) and SUV(max) (mean, 3.43 [64.9%]; p < 0.0001). OTR evaluated subjectively, correlated well with changes in SUV(max) (p < 0.0001). No statistically significant association was found between changes in tumor density and changes in SUV(max) (p = 0.3088), but 70% (14/20) of the patients with tumors that showed response on FDG PET exhibited at least a partial response by a change in tumor density. Tumor size was found to have decreased significantly 2 months after treatment (p = 0.0070). However, in 75% of the patients, the disease was stable according to the traditional tumor response criteria of RECIST. CONCLUSION: FDG PET is sensitive and specific for evaluating tumor response but cannot be used in patients whose baseline FDG PET results are negative for tumors. Although subjective evaluation was a better indicator of treatment response than was tumor density alone, the tumor density measurement is a good indicator and provides a reliable quantitative means of monitoring the tumor. RECIST, using only tumor size, was unreliable for monitoring GISTs during the early stage of imatinib mesylate treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New Guidelines to Evaluate the Response to Treatment in Solid Tumors
Therasse, P., Arbuck, S. G., Eisenhauer, E. A., Wanders, J., Kaplan, R. S., Rubinstein, L., Verweij, J., Van Glabbeke, M., van Oosterom, A. T., Christian, M. C., et al. (2000) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/92.3.205 · Cited by 15,660
Cited by
From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777
“Additional anatomic characteristics of GIST, such as the development of mural nodules, but not necessarily with tumor growth because of the predominantly cystic nature of the tumors, are indicative of progression and of a poor outcome (48,49).”
BackgroundInfluentialChoi, H., Charnsangavej, C., Faria, S. C., Macapinlac, H. A., Burgess, M. A., Patel, S. R., Chen, L. L., Podoloff, D. A., & Benjamin, R. S. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.07.3049 · Cited by 1,520
Self-citationGastrointestinal stromal tumour
Rubin, B. P., Heinrich, M. C., & Corless, C. L. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60780-6 · Cited by 1,036
Heo, J., Reid, T., Ruo, L., Breitbach, C. J., Rose, S., Bloomston, M., Cho, M., Lim, H. Y., Chung, H. C., Kim, C. W., et al. (2013) · Nature Medicine · doi:10.1038/nm.3089 · Cited by 779
Intravenous delivery of a multi-mechanistic cancer-targeted oncolytic poxvirus in humans
Breitbach, C. J., Burke, J., Jonker, D., Stephenson, J., Haas, A. R., Chow, L. Q. M., Nieva, J., Hwang, T.-H., Moon, A., Patt, R., et al. (2011) · Nature · doi:10.1038/nature10358 · Cited by 551
Metadata
- Authors
- Choi, H., Charnsangavej, C., Faria, S. D. C., Tamm, E. P., Benjamin, R. S., Johnson, M. M., Macapinlac, H. A., & Podoloff, D. A.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2004-12
- Volume
- 183
- Issue
- 6
- Pages
- 1619-1628
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2062428732
- Cited by
- 459
- References
- 1
- FWCI
- 15.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CT Evaluation of the Response of Gastrointestinal Stromal Tumors After Imatinib Mesylate Treatment: A Quantitative Analysis Correlated with FDG PET Findings. https://app.cochat.ai/papers/10.2214/ajr.183.6.01831619
- The paper
- Choi, H., Charnsangavej, C., Faria, S. D. C., Tamm, E. P., Benjamin, R. S., Johnson, M. M., Macapinlac, H. A., & Podoloff, D. A. (2004). CT Evaluation of the Response of Gastrointestinal Stromal Tumors After Imatinib Mesylate Treatment: A Quantitative Analysis Correlated with FDG PET Findings. American Journal of Roentgenology. https://doi.org/10.2214/ajr.183.6.01831619
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.