Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 173

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Determination of Splenomegaly by CT: Is There a Place for a Single Measurement?

Bezerra, Alexandre S., D'Ippolito, Giuseppe, Faintuch, Salomão, Szejnfeld, Jacob, Ahmed, Muneeb · 2005 · American Journal of Roentgenology

Abstract

OBJECTIVE: Our objective was to determine if there is a single parameter that can be used as a marker of splenomegaly using CT. MATERIALS AND METHODS: Splenic length, width, and thickness were measured in 249 CT scans and multidimensional indexes were obtained from the multiplication of these measurements. Volume was calculated by summing the volumes of multiple contiguous scans. The relationship of the spleen to the left liver lobe and inferior third of the left kidney was also evaluated. Linear equations were obtained to correlate each measurement to the splenic volume. RESULTS: The unidimensional measurements with best correlation to volume were splenic length (r = 0.81, p < 0.01) and width (r = 0.804, p < 0.01). Correlation was better for the multidimensional indexes (r = 0.95, p < 0.01). Using a previously described upper limit of normality for splenic volume of 314.5 cm3 in the linear regression equation obtained, a maximum spleen length of 9.76 cm was the upper limit of normality. The relation of the lowest point of the spleen to the inferior third of the kidney also showed that if the spleen reached or extended below this portion of the kidney, it could be used as evidence of splenomegaly (p < 0.005), although it had a low sensitivity. CONCLUSION: Splenic length and multidimensional indexes correlate well with splenic CT volume. A splenic length of 9.76 cm can be used to accurately diagnose splenomegaly and can replace multiple-measurement, time-consuming methods in the clinical routine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.184.5.01841510

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 173

Metadata

Authors
Bezerra, A. S., D'Ippolito, G., Faintuch, S., Szejnfeld, J., & Ahmed, M.
Venue
American Journal of Roentgenology
Published
2005-05
Volume
184
Issue
5
Pages
1510-1513
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2127567384
Cited by
173
References
1
FWCI
3.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of Splenomegaly by CT: Is There a Place for a Single Measurement? https://app.cochat.ai/papers/10.2214/ajr.184.5.01841510
The paper
Bezerra, A. S., D'Ippolito, G., Faintuch, S., Szejnfeld, J., & Ahmed, M. (2005). Determination of Splenomegaly by CT: Is There a Place for a Single Measurement? American Journal of Roentgenology. https://doi.org/10.2214/ajr.184.5.01841510

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.