Rapid Musculoskeletal MRI in 2021: Clinical Application of Advanced Accelerated Techniques
Abstract
OBJECTIVE. The purpose of this article is to provide a practice-focused review of the clinical application of advanced acceleration techniques for rapid musculoskeletal MRI examinations. CONCLUSION. Parallel imaging, simultaneous multislice acquisition, compressed sensing-based sampling, and synthetic MRI techniques provide unprecedented opportunities for rapid musculoskeletal MRI examinations. For 2D and 3D fast spin-echo and turbo spin-echo pulse sequences, acceleration factors between 3 and 8 can be realized in clinical practice, amounting to a time savings of 66-85% when compared with unaccelerated acquisitions.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Combining CT-based models with biomarkers and clinical data could create the backbone of thorough, individualized diagnostic systems.
“Combining CT-based models with biomarkers and clinical data could create the backbone of thorough, individualized diagnostic systems [77].”
From Biomarker-Guided Imaging and AI-Augmented Diagnosis of Degenerative Joint Disease (2025) · cites this paper as [77]
Cited by
Sorted by citations
Biomarker-Guided Imaging and AI-Augmented Diagnosis of Degenerative Joint Disease
Kumar, R., Sporn, K., Borole, A., Khanna, A., Gowda, C., Paladugu, P., Ngo, A., Jagadeesan, R., Zaman, N., & Tavakkoli, A. (2025) · Diagnostics · doi:10.3390/diagnostics15111418 · Cited by 10 · see citing works
“Combining CT-based models with biomarkers and clinical data could create the backbone of thorough, individualized diagnostic systems [77].”
- Authors
- Fritz, J., Guggenberger, R., & Grande, F. D.
- Affiliations
- New York University (US)
- University Hospital Zurich (CH)
- Istituto Imaging della Svizzera Italiana (CH)
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2021-03
- Volume
- 216
- Issue
- 3
- Pages
- 718-733
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W3128463713
- Cited by
- 121
- References
- 0
- Citations by year
- 2026: 13 · 2025: 19 · 2024: 21 · 2023: 27 · 2022: 21 · 2021: 20
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Roentgenology (publishedVersion)
- PubMed (publishedVersion)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › MRI in cancer diagnosis
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Keywords
- accelerated MRI, musculoskeletal MRI, parallel imaging, compressed sensing, synthetic MRI, fast spin echo, scan time reduction, acceleration factor
- MeSH terms
- Humans, Magnetic Resonance Imaging, Musculoskeletal System, Time Factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review