Cited by 19Advanced X-ray and CT ImagingBone health and osteoporosis researchDigital Radiography and Breast Imaging

Opportunistic Bone Mineral Density Measurement Using Photon-Counting Detector CT Spectral Localizer Images: A Prospective Study

El Sadaney, Ahmed O., Ferrero, Andrea, Rajendran, Kishore, Jasper, Soren, Mazza, Gina L., Broski, Stephen M., Shanblatt, Elisabeth, Nowak, Tristan +3 more·2025·American Journal of Roentgenology

Abstract

BACKGROUND. Spectral localizer images from photon-counting detector (PCD) CT can be used for bone mineral density (BMD) evaluation given their 2D projectional nature and material decomposition capability. As all CT examinations include localizer images, this approach could allow opportunistic osteoporosis screening of patients undergoing clinically indicated imaging with PCD CT. OBJECTIVE . The purpose of this study was to assess the use of PCD CT spectral localizer images for opportunistic derivation of areal BMD (aBMD) values and T-scores, with dual-energy x-ray absorptiometry (DEXA) used as the reference standard. METHODS. This prospective study included patients 18 years old or older who were scheduled for a clinically indicated lumbar spine CT examination between October 2023 and February 2024 and who underwent DEXA within the previous 13 months or were scheduled for DEXA within the subsequent 13 months. Participants underwent lumbar spine CT by PCD CT including spectral localizer images. The lumbar spine aBMD was extracted from clinical DEXA reports. ROIs were placed on lumbar vertebral bodies and background soft tissues to extract areal densities from spectral localizer images using material decomposition; areal densities were used to derive lumbar spine aBMD values. The aBMD values were used to derive T-scores, which were classified as representing normal (≥ -1.0) or abnormal ( RESULTS. The study included 51 participants (31 women and 20 men; mean age, 62 years [range…

Integrity signals

Registry

Crossref · 10.2214/ajr.24.31909

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The patients in our study had an average BMI of 25.3 kg/m2, whereas the cohort in the study by El Sadaney et al had an average BMI of 30 kg/m2.

    “The patients in our study had an average BMI of 25.3 kg/m2, whereas the cohort in the study by El Sadaney et al22 had an average BMI of 30 kg/m2.”
  • El Sadaney et al accepted a wider interval between DXA and spectral localizer radiographs from 13 months before to 13 months after CT, whereas in our prospective study, the median time of DXA was 45 days after CT.

    “El Sadaney et al22 accepted a wider interval between DXA and spectral localizer radiographs from 13 months before to 13 months after CT, whereas in our prospective study, the median time of DXA was 45 days after CT.”
  • El Sadaney et al found a poor agreement between DXA and spectral localizer radiograph-derived aBMD values as evidenced by Lin's concordance correlation coefficients between 0.55 and 0.68.

    “El Sadaney et al22 compared the aBMD from spectral localizer radiographs to DXA. In distinction to our study, authors found a poor agreement between DXA and spectral localizer radiograph-derived aBMD values as evidenced by Lin's concordance correlation coefficients between 0.55 and 0.68.”
  • El Sadaney et al performed segmentations of the lumbar vertebrae blinded from corresponding DXA segmentations, whereas we performed a readout in spectral localizer radiographs exactly matching the DXA segmentations; this matching of segmentations between modalities minimizes a segmentation bias, which may introduce differences not inherently related to the modalities.

    “Finally, El Sadaney et al22 performed segmentations of the lumbar vertebrae blinded from corresponding DXA segmentations, whereas we performed a readout in spectral localizer radiographs exactly matching the DXA segmentations. This matching of segmentations between modalities minimizes a segmentation bias, which may introduce differences not inherently related to the modalities.”
  • Differences in body constitution, possibly also induced by therapy, may have contributed to the weaker correlation between DXA and localizer radiographs in El Sadaney et al.

    “Differences in body constitution, possibly also induced by therapy, may have contributed to the weaker correlation between DXA and localizer radiographs in El Sadaney et al.22”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
El Sadaney, A. O., Ferrero, A., Rajendran, K., Jasper, S., Mazza, G. L., Broski, S. M., Shanblatt, E., Nowak, T., Fletcher, J. G., McCollough, C. H., & Baffour, F. I.
Affiliations
  • Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905.
  • Mayo Clinic (US)
  • Siemens Healthcare (United States) (US)
Venue
American Journal of Roentgenology
Published
2025-01
Volume
224
Issue
1
Pages
e2431909-e2431909
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W4403894976
Cited by
19
References
1
Citations by year
2026: 9 · 2025: 8 · 2024: 2
FWCI
2.09
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Roentgenology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Digital Radiography and Breast Imaging
Keywords
bone mineral density, opportunistic screening, osteoporosis screening, photon-counting CT, material decomposition, dual-energy CT
MeSH terms
Adult, Aged, Aged, 80 and over, Female, Humans, Lumbar Vertebrae, Male, Middle Aged, Osteoporosis, Prospective Studies, Tomography, X-Ray Computed, Absorptiometry, Photon, Bone Density, Photons

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review