The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cumulative Patency of Contemporary Fistulas versus Grafts (2000–2010)
Open accessAbstract
Summary: Background and objectives: Comparisons of fistulas and grafts often overlook the high primary failure rate of fistulas. This study compared cumulative patency (time from access creation to permanent failure) of fistulas and grafts. Design, setting, participants, & measurements: Vascular accesses of 1140 hemodialysis patients from two centers (Toronto and London, Ontario, Canada, 2000−2010) were analyzed. Cumulative patency was compared between groups using Kaplan-Meier survival curves and log-rank tests. Hazard ratios (HRs) for fistula failure relative to grafts and 95% confidence intervals (95% CIs) are reported. Results: There were 1012 (88.8%) fistulas and 128 (11.2%) grafts. The primary failure rate was two times greater for fistulas than for grafts: 40% versus 19% ( P< 0.001). Cumulative patency did not differ between fistulas and grafts for the patients’ first access (median, 7.4 versus 15.0 months, respectively [HR, 0.99; 95% CI, 0.79−1.23; P= 0.85]) or for 600 with a subsequent access (7.0 versus 9.0 months [HR, 0.93; 95% CI, 0.77−1.13; P= 0.39]). However, when primary failures were excluded, cumulative patency became significantly longer for fistulas than for grafts for both first and subsequent accesses (61.9 versus 23.8 months [HR, 0.56; 95% CI, 0.43−0.74; P <0.001] and 42.8 versus 15.9 months [HR, 0.56; 95% CI, 0.44−0.72; P <0.001]). Results were similar for forearm and upper-arm accesses. Compared with functioning fistulas, grafts necessitated twice as many angioplasties (1.4 versus 3.2/1000 days, respectively; P< 0.001) and significantly more thrombolysis interventions (0.06 versus 0.98/1000 days; P< 0.001) to maintain patency once matured and successfully used for dialysis. Conclusions: Cumulative patency did not differ between fistulas and grafts; however, grafts necessitated more interventions to maintain functional patency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xi, W., Harwood, L., Diamant, M. J., Brown, J. B., Gallo, K., Sontrop, J. M., MacNab, J. J., & Moist, L. M. (2011) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfr055 · Cited by 131
Self-citation
Cited by
KDOQI Clinical Practice Guideline for Vascular Access: 2019 Update
Lok, C. E., Huber, T. S., Lee, T., Shenoy, S., Yevzlin, A. S., Abreo, K., Allon, M., Asif, A., Astor, B. C., Glickman, M. H., et al. (2020) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2019.12.001 · Cited by 2,590
Self-citationPatency Rates of the Arteriovenous Fistula for Hemodialysis: A Systematic Review and Meta-analysis
Al-Jaishi, A. A., Oliver, M. J., Thomas, S. M., Lok, C. E., Zhang, J. C., Garg, A. X., Kosa, S. D., Quinn, R. R., & Moist, L. M. (2014) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2013.08.023 · Cited by 680
Self-citationVascular Tissue Engineering: Progress, Challenges, and Clinical Promise
Song, H.-H. G., Rumma, R. T., Ozaki, C. K., Edelman, E. R., & Chen, C. S. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.009 · Cited by 476
Lawson, J. H., Glickman, M. H., Ilzecki, M., Jakimowicz, T., Jaroszynski, A., Peden, E. K., Pilgrim, A. J., Prichard, H. L., Guziewicz, M., Przywara, S., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)00557-2 · Cited by 381
UK Kidney Association Clinical Practice Guideline on vascular access for haemodialysis
Aitken, E., Anijeet, H., Ashby, D., Barrow, W., Calder, F., Dowds, B., Fielding, C., Gilbert, J., Jones, R., Karunanithy, N., et al. (2025) · BMC Nephrology · doi:10.1186/s12882-025-04374-y · Cited by 42
Metadata
- Authors
- Lok, C. E., Sontrop, J. M., Tomlinson, G., Rajan, D., Cattral, M., Oreopoulos, G., Harris, J., & Moist, L.
- Venue
- Clinical Journal of the American Society of Nephrology
- Published
- 2013-05
- Volume
- 8
- Issue
- 5
- Pages
- 810-818
- ISSN
- 1555-9041 (ISSN-L)
- OpenAlex
- W2133123627
- Cited by
- 237
- References
- 1
- FWCI
- 30.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.