CoChat

Increased Hemodialysis Catheter Use in Canada and Associated Mortality Risk: Data from the Canadian Organ Replacement Registry 2001–2004

Open access
Moist, Louise M., Trpeski, Lilyanna, Na, Yingbo, Lok, Charmaine E. · 2008 · Clinical Journal of the American Society of Nephrology
Cited by 148

The DOI matches its Crossref record.

Abstract

BACKGROUND AND OBJECTIVES: The 1999 Canadian vascular access guidelines recommend the fistula as the access of choice. The study describes the trends in hemodialysis access use, variation among provinces, and the association with mortality from 2001 to 2004. DESIGN, SETTING, PARTICIPANTS AND MEASUREMENTS: An observational study of adult patients registered in Canadian Organ Replacement Registry on hemodialysis. Access trends were examined among incident and prevalent hemodialysis patients adjusted for age, sex, body mass index, late referral, race, smoking status, province, etiology of end-stage renal disease, and comorbidities. Cox proportional hazard regression analysis was used to analyze risk for death for patients followed to December 31, 2005. RESULTS: From 2001 to 2004, incident catheter use increased from 76.8% to 79.1%, fistulas decreased from 21.6% to 18.6%, and grafts remained between 2.1% to 2.6%. Prevalent catheter use increased from 41.8% to 51.7%, and fistulas and grafts decreased from 46.8% to 41.6% and 11.4% to 6.7%, respectively. There was significant variation in incident and prevalent fistulae use among the provinces. Adjustment for differences in patient characteristics did not change these trends. Incident catheter use was associated with a 6 times greater risk of death compared with fistula or graft use combined. CONCLUSIONS: In Canada there has been a decrease in fistulae and grafts with a subsequent increase in catheters that is not explained by changes in patient characteristics. Vascular access use varied by province, suggesting differences in practice patterns. Because incident catheter use was associated with increased mortality, urgent measures are needed to develop strategies to decrease catheter use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2215/cjn.01240308

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 148

Metadata

Authors
Moist, L. M., Trpeski, L., Na, Y., & Lok, C. E.
Venue
Clinical Journal of the American Society of Nephrology
Published
2008-11
Volume
3
Issue
6
Pages
1726-1732
ISSN
1555-9041 (ISSN-L)
OpenAlex
W2103629829
Cited by
148
References
0
FWCI
17.42
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Increased Hemodialysis Catheter Use in Canada and Associated Mortality Risk: Data from the Canadian Organ Replacement Registry 2001–2004. https://app.cochat.ai/papers/10.2215/cjn.01240308
The paper
Moist, L. M., Trpeski, L., Na, Y., & Lok, C. E. (2008). Increased Hemodialysis Catheter Use in Canada and Associated Mortality Risk: Data from the Canadian Organ Replacement Registry 2001–2004. Clinical Journal of the American Society of Nephrology. https://doi.org/10.2215/cjn.01240308

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.