Dialysis-Induced Regional Left Ventricular Dysfunction Is Ameliorated by Cooling the Dialysate

Selby, Nicholas M., Burton, James O., Chesterton, Lindsay J., McIntyre, Christopher W. · 2006 · Clinical Journal of the American Society of Nephrology

Abstract

Dialysis patients who develop cardiac failure have a poor prognosis. Recurrent subclinical myocardial ischemia is important in the genesis of heart failure in nondialysis patients. It has previously been demonstrated that subclinical ischemia occurs during hemodialysis; therefore, this study examined whether the improved stability of cool-temperature dialysis lessens this phenomenon. Ten patients who were prone to intradialytic hypotension entered a randomized, crossover study to compare the development of dialysis-induced left ventricular (LV) regional wall motion abnormalities (RWMA) at dialysate temperatures of 37 and 35 degrees C. Serial echocardiography with quantitative analysis was used to assess ejection fraction and regional systolic LV function. BP and hemodynamic variables were measured using continuous pulse wave analysis. The severity of thermal symptoms was scored using a simple questionnaire. Forty-nine new RWMA developed in nine patients during hemodialysis with dialysate at 37 degrees C (HD(37)), compared with thirteen RWMA that developed in four patients during HD(35) (odds ratio 3.8; 95% confidence interval 2.1 to 6.9). The majority of RWMA displayed improved function by 30 min after dialysis. Overall, regional systolic LV function was significantly more impaired during HD(37) (P < 0.001). BP was higher during HD(35), with fewer episodes of hypotension as a result of a higher peripheral resistance and no difference in stroke volume. The development of thermal symptoms was heterogeneous, with most patients tolerating HD(35) well. This study confirms previous findings of reversible LV RWMA that develop during hemodialysis. It also shows that this phenomenon can be ameliorated by reducing dialysate temperature, a simple intervention with no cost implications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2215/cjn.02010606

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 175

Metadata

Authors
Selby, N. M., Burton, J. O., Chesterton, L. J., & McIntyre, C. W.
Venue
Clinical Journal of the American Society of Nephrology
Published
2006-11
Volume
1
Issue
6
Pages
1216-1225
ISSN
1555-9041 (ISSN-L)
OpenAlex
W2120295194
Cited by
175
References
1
FWCI
4.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dialysis-Induced Regional Left Ventricular Dysfunction Is Ameliorated by Cooling the Dialysate. https://app.cochat.ai/papers/10.2215/cjn.02010606
The paper
Selby, N. M., Burton, J. O., Chesterton, L. J., & McIntyre, C. W. (2006). Dialysis-Induced Regional Left Ventricular Dysfunction Is Ameliorated by Cooling the Dialysate. Clinical Journal of the American Society of Nephrology. https://doi.org/10.2215/cjn.02010606

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.