Ultrasound-Guided Femoral Dialysis Access Placement: A Single-Center Randomized Trial
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND OBJECTIVES: Insertion of dialysis catheters (DCs) is a prerequisite for successful initiation of hemodialysis. We attempted to determine if ultrasonography-guided (USG) insertion was superior and safer than the anatomical landmark-guided technique (ALT) for the femoral vein (FV). DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: This was a randomized prospective study on 110 patients requiring FV DCs in a tertiary care hospital. Patients were randomized into two groups: USG and ALT. Data were collected on demography, operator experience, and side of insertion. The USG group had their catheters inserted under USG guidance, whereas the ALT group had their DC inserted by ALT. Outcome measures included successful insertion of DC, number of attempts, and complications. RESULTS: Both groups were comparable regarding age and gender of patients, operator experience, and the side of catheterization. The overall success rate was 89.1%, with 80% using ALT and 98.2% under USG guidance (P = 0.002). First attempt success rate was 54.5% in the ALT group as compared with 85.5% in the USG group (P = 0.000). The complication rate was 18.2% in the ALT group and 5.5% in the USG group (P = 0.039). The odds ratio (OR) for complications with two or more attempts was 10.73 with a relative risk (RR) of 3.2. The OR for successful insertion using USG was 13.5 (95% CI: 1.7 to 108.7). CONCLUSIONS: USG significantly improves success rate, reduces number of attempts, and decreases the incidence of complications related to FV DC insertion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2005 Annual Report: ESRD Clinical Performance Measures Project
Kinney, R. (2006) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2006.07.015 · Cited by 211
Cited by
KDOQI Clinical Practice Guideline for Vascular Access: 2019 Update
Lok, C. E., Huber, T. S., Lee, T., Shenoy, S., Yevzlin, A. S., Abreo, K., Allon, M., Asif, A., Astor, B. C., Glickman, M. H., et al. (2020) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2019.12.001 · Cited by 2,590
Frankel, H. L., Kirkpatrick, A. W., Elbarbary, M., Blaivas, M., Desai, H., Evans, D., Summerfield, D. T., Slonim, A., Breitkreutz, R., Price, S., et al. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000001216 · Cited by 494
Troianos, C. A., Hartman, G. S., Glas, K. E., Skubas, N. J., Eberhardt, R. T., Walker, J. D., & Reeves, S. T. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.09.021 · Cited by 420
Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization
Brass, P., Hellmich, M., Kolodziej, L., Schick, G., & Smith, A. F. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011447 · Cited by 320
Lamperti, M., Biasucci, D. G., Disma, N., Pittiruti, M., Breschan, C., Vailati, D., Subert, M., Traškaitė, V., Macas, A., Estebe, J.-P., et al. (2020) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000001180 · Cited by 316
Metadata
- Authors
- Prabhu, M. V., Juneja, D., Gopal, P. B., Sathyanarayanan, M., Subhramanyam, S., Gandhe, S., & Nayak, K. S.
- Venue
- Clinical Journal of the American Society of Nephrology
- Published
- 2010-02
- Volume
- 5
- Issue
- 2
- Pages
- 235-239
- ISSN
- 1555-9041 (ISSN-L)
- OpenAlex
- W2131146703
- Cited by
- 126
- References
- 1
- FWCI
- 10.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound-Guided Femoral Dialysis Access Placement: A Single-Center Randomized Trial. https://app.cochat.ai/papers/10.2215/cjn.04920709
- The paper
- Prabhu, M. V., Juneja, D., Gopal, P. B., Sathyanarayanan, M., Subhramanyam, S., Gandhe, S., & Nayak, K. S. (2010). Ultrasound-Guided Femoral Dialysis Access Placement: A Single-Center Randomized Trial. Clinical Journal of the American Society of Nephrology. https://doi.org/10.2215/cjn.04920709
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.