CoChat

Evaluating Approaches for the Diagnosis of Hemodialysis Catheter–Related Bloodstream Infections

Open access
Quittnat Pelletier, Friederike, Joarder, Mohammad, Poutanen, Susan M., Lok, Charmaine E. · 2016 · Clinical Journal of the American Society of Nephrology
Cited by 60

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background and objectives: Guideline–recommended diagnostic criteria for hemodialysis (HD) catheter–related bloodstream infections (CRBSIs) are based on data from indwelling central catheters in patients not on HD and non-HD situations, and upon which peripheral vein cultures are the gold standard. We aimed to examine the validity of these criteria in patients on HD. Design, settings, participants, & measurements: Adult patients on in-center HD using catheters were prospectively followed from 2011 to 2014 at a large academic–based HD facility (Toronto, Canada). When a CRBSI was suspected, blood culture sets were obtained from four sites (peripheral vein, both catheter hubs, and HD circuit) to determine the guideline–recommended differential time to positivity (DTTP). DTTP criteria were met when catheter hub cultures turned positive ≥120 minutes before peripheral vein cultures. The sensitivity, specificity, and accuracy were first calculated using peripheral vein cultures as the gold standard and then these same calculations were repeated with additional information, including exit site/catheter tip and HD circuit cultures, as the true gold standard. The feasibility of obtaining peripheral vein cultures was determined. Results: Of 178 suspected CRBSIs, 100 had peripheral vein blood cultures. Using the true gold standard, sensitivity, specificity, and accuracy of blood culture results were highest in samples from the HD circuit (93.5%, 100%, and 95%, respectively). The guideline recommended combination of peripheral vein and arterial hub blood cultures was the least sensitive, specific, and accurate (91.7%, 93.1%, and 92.7%, respectively). The diagnostic criteria using measured DTTP were met in less than one third of events. Conclusions: In patients on HD, blood culture results are the most sensitive, specific, and accurate for diagnosing CRBSIs when taken from the HD circuit and the venous catheter hub, and blood culture results are the least sensitive, specific, and accurate in any combination with peripheral vein cultures. The DTTP does not increase diagnostic accuracy, reducing the necessity for venipuncture and its potential vein damage. Future guidelines should consider the applicability of criterion on specific patient populations and tailor them accordingly.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2215/cjn.09110815

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Quittnat Pelletier, F., Joarder, M., Poutanen, S. M., & Lok, C. E.
Venue
Clinical Journal of the American Society of Nephrology
Published
2016-04-01
Volume
11
Issue
5
Pages
847-854
ISSN
  • 1555-9041 (ISSN-L)
  • 1555-905X
OpenAlex
W2320862518
Cited by
60
References
1
FWCI
10.93
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.