Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 183

The DOI matches its Crossref record.

National Healthcare Safety Network (NHSN) Dialysis Event Surveillance Report for 2014

Open access
Nguyen, Duc B., Shugart, Alicia, Lines, Christi, Shah, Ami B., Edwards, Jonathan, Pollock, Daniel, Sievert, Dawn, Patel, Priti R. · 2017 · Clinical Journal of the American Society of Nephrology

Abstract

Background and objectives: Persons receiving outpatient hemodialysis are at risk for bloodstream and vascular access infections. The Centers for Disease Control and Prevention conducts surveillance for these infections through the National Healthcare Safety Network. We summarize 2014 data submitted to National Healthcare Safety Network Dialysis Event Surveillance. Design, setting, participants, & measurements: Dialysis facilities report three types of dialysis events (bloodstream infections; intravenous antimicrobial starts; and pus, redness, or increased swelling at the hemodialysis vascular access site). Denominator data consist of the number of hemodialysis outpatients treated at the facility during the first 2 working days of each month. We calculated dialysis event rates stratified by vascular access type (e.g., arteriovenous fistula, arteriovenous graft, or central venous catheter) and standardized infection ratios (comparing individual facility observed with predicted numbers of infections) for bloodstream infections. We described pathogens identified among bloodstream infections. Results: A total of 6005 outpatient hemodialysis facilities reported dialysis event data for 2014 to the National Healthcare Safety Network. These facilities reported 160,971 dialysis events, including 29,516 bloodstream infections, 149,722 intravenous antimicrobial starts, and 38,310 pus, redness, or increased swelling at the hemodialysis vascular access site events; 22,576 (76.5%) bloodstream infections were considered vascular access related. Most bloodstream infections (63.0%) and access-related bloodstream infections (69.8%) occurred in patients with a central venous catheter. The rate of bloodstream infections per 100 patient-months was 0.64 (0.26 for arteriovenous fistula, 0.39 for arteriovenous graft, and 2.16 for central venous catheter). Other dialysis event rates were also highest among patients with a central venous catheter. Facility bloodstream infection standardized infection ratio distribution was positively skewed with a median of 0.84. Staphylococcus aureus was the most commonly isolated bloodstream infection pathogen (30.6%), and 39.5% of S. aureus isolates tested were resistant to methicillin. Conclusions: The 2014 National Healthcare Safety Network Dialysis Event data represent nearly all United States outpatient dialysis facilities. Rates of infection and other dialysis events were highest among patients with a central venous catheter compared with other vascular access types. Surveillance data can help define the epidemiology of important infections in this patient population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2215/cjn.11411116

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 183

Metadata

Authors
Nguyen, D. B., Shugart, A., Lines, C., Shah, A. B., Edwards, J., Pollock, D., Sievert, D., & Patel, P. R.
Venue
Clinical Journal of the American Society of Nephrology
Published
2017-06-29
Volume
12
Issue
7
Pages
1139-1146
ISSN
  • 1555-9041 (ISSN-L)
  • 1555-905X
OpenAlex
W2727914648
Cited by
183
References
0
FWCI
26.72
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: National Healthcare Safety Network (NHSN) Dialysis Event Surveillance Report for 2014. https://app.cochat.ai/papers/10.2215/cjn.11411116
The paper
Nguyen, D. B., Shugart, A., Lines, C., Shah, A. B., Edwards, J., Pollock, D., Sievert, D., & Patel, P. R. (2017). National Healthcare Safety Network (NHSN) Dialysis Event Surveillance Report for 2014. Clinical Journal of the American Society of Nephrology. https://doi.org/10.2215/cjn.11411116

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.