Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 348

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Diffusion tensor MRI as a biomarker in axonal and myelin damage

Open access
Aung, Wint Yan, Mar, Soe, Benzinger, Tammie LS·2013·Imaging in Medicine

Abstract

Diffusion tensor imaging has been used extensively as a research tool to understand the structural changes associated with white matter pathology. Using water diffusion as the basis to construct anatomic details, diffusion tensor imaging offers the potential to identify structural and functional adaptations before gross anatomical changes, such as lesions and tumors, become apparent on conventional MRI. Over the past 10 years, further parameters, such as axial and radial diffusivity, have been developed to characterize white matter changes specific to axons and myelin. In this paper, the potential application and outstanding issues on the use of diffusion tensor imaging directional diffusivity as a biomarker in axonal and myelin damage in neurological disorders will be reviewed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2217/iim.13.49

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

Metadata

Authors
Aung, W. Y., Mar, S., & Benzinger, T. L.
Venue
Imaging in Medicine
Published
2013-10
Volume
5
Issue
5
Pages
427-440
ISSN
  • 1755-5191 (ISSN-L)
  • 1755-5205
OpenAlex
W2131307089
Cited by
348
References
17
FWCI
4.52
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.