THE CYTOSKELETON IN MYELINATED AXONS: SERIAL SECTION STUDY
The DOI matches its Crossref record, with a small difference in title or year.
Abstract
The three-dimensional arrangement and continuity of microtubules and neurofilaments in myelinated axons of the mouse saphenous nerve were analyzed using the serial section method.The course of individual microtubules was followed in two sets of transversely cut serial sections for the internodal region and in one set for the nodal region, and approximately 97%, 96%, and 94% of all microtubules, respectively, were continuous within the examined 10 pm-long segments.Assuming that all microtubules are homogeneous in length, their average length was calculated to be about 370-760 nm.Furthermore, the number of microtubules was not constant but fluctuated slightly along the 185 rim-long segment of one myelinated axon.The results favor the hypothesis that microtubules in the myelinated axon are long, but do not extend the entire length of the axon.On the other hand, neurofilaments decreased remarkably in number at the node of Ranvier, indicating that most of them were discontinuous at the nodal region.KEY WORDS cytoskeleton / microtubule / neurofilament / myelinated axon /serial section '*3 5' U! Lr'I IO Oi Ll "O 0-I 'H J G ¢"'%'£ 5 2. .3'.37 2'? .:23 190 er 73 Q 9.x.'B 2621:-,:'.a1*s
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In myelinated axons, EM work has shown that microtubules are mostly continuous through nodes of Ranvier (42).”
From Axonal transport: Driving synaptic function (2019) · cites this paper as [42]
In the citing paper
“In these specialized regions of shortened axonal diameter, the microtubule number remained virtually unchanged but the microtubule bundle was found to be more compacted (42) and to contain fasciculated microtubules, a feature that was previously thought to be unique to the AIS (44).”
From Axonal transport: Driving synaptic function (2019) · cites this paper as [42]
In the citing paper
“Estimates of microtubule length range from 0.05 to 40 μm in developing axons of cultured hippocampal neurons (40), and up to several hundred microns in some neuronal subtypes (41–43).”
From Axonal transport: Driving synaptic function (2019) · cites this paper as [42]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Axonal growth in response to experimentally applied mechanical tension
Bray, D. (1984) · Developmental Biology · doi:10.1016/0012-1606(84)90202-1 · Cited by 369
Baas, P. W., & Black, M. M. (1990) · The Journal of cell biology · doi:10.1083/jcb.111.2.495 · Cited by 362
Axonal transport: Driving synaptic function
Guedes-Dias, P., & Holzbaur, E. L. F. (2019) · Science · doi:10.1126/science.aaw9997 · Cited by 355
Changes in microtubule number and length during axon differentiation
Yu, W., & Baas, P. (1994) · The Journal of Neuroscience · doi:10.1523/jneurosci.14-05-02818.1994 · Cited by 213
Axonal tubulin and axonal microtubules: biochemical evidence for cold stability
Brady, S. T., Tytell, M., & Lasek, R. J. (1984) · The Journal of cell biology · doi:10.1083/jcb.99.5.1716 · Cited by 170
Metadata
- Authors
- TSUKITA, S., & ISHIKAWA, H.
- Venue
- Biomedical Research
- Publisher
- Biomedical Research Press
- Published
- 1981
- Volume
- 2
- Issue
- 4
- Pages
- 424-437
- ISSN
- 0388-6107
- 1880-313X
- Cited by
- 72
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: THE CYTOSKELETON IN MYELINATED AXONS: SERIAL SECTION STUDY. https://app.cochat.ai/papers/10.2220/biomedres.2.424
- The paper
- TSUKITA, S., & ISHIKAWA, H. (1981). THE CYTOSKELETON IN MYELINATED AXONS: SERIAL SECTION STUDY. Biomedical Research. https://doi.org/10.2220/biomedres.2.424
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.