Detection of Atrial Fibrillation in ECG Hand-held Devices Using a Random Forest Classifier
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Atrial Fibrillation (AF) is characterized by chaotic electrical impulses in the atria, which leads to irregular heartbeats and can develop blood clots and stroke.Therefore, early detection of AF is crucial for increasing the success rate of the treatment.This study is focused on detection of AF rhythm using hand-held ECG monitoring devices, in addition to three other classes: normal or sinus rhythm, other rhythms, and too noisy to analyze.The pipeline of the proposed method consists of three major components: preprocessing and feature extraction, feature selection, and classification.In total, 491 hand-crafted features are extracted.Then, 150 features are selected in a feature ranking procedure.The selected features are from time, frequency, time-frequency domains, and phase space reconstruction of the ECG signals.In the final stage, a random forest classifier is used to classify the selected features into one of the four aforementioned ECG classes.Using the scoring mechanism provided by PhysioNet/Computing in Cardiology (CinC) Challenge 2017, the overall score (mean±std) of 81.9±2.6% is achieved over the training dataset in 10-fold crossvalidation.The proposed algorithm tied for the first place in the PhysioNet/CinC Challenge 2017 with an overall score of 82.6% (rounded to 83%) on the unseen test dataset.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detecting strange attractors in turbulence
Takens, F. (1981) · Lecture Notes in Mathematics · doi:10.1007/bfb0091924 · Cited by 10,459 · cited 1×
“The first feature is defined as if an ellipsoid can be fitted in the 2-D phase space with lag 1 (reconstructed based on Takens’ delay embedding theory [15]).”
BackgroundWorldwide Epidemiology of Atrial Fibrillation: A Global Burden of Disease 2010 Study
Chugh, S. S., Havmoeller, R., Narayanan, K., Singh, D., Rienstra, M., Benjamin, E. J., Gillum, R. F., Kim, Y.-H., McAnulty, J. H., Zheng, Z.-J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005119 · Cited by 4,506 · cited 1×
“5 million in 2010 [1], and its rate is increasing based on regional studies [2].”
Background2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw313 · Cited by 1,403
Cited by
Lin, C.-S., Lin, C., Fang, W.-H., Hsu, C.-J., Chen, S.-J., Huang, K.-H., Lin, W.-S., Tsai, C.-S., Kuo, C.-C., Chau, T., et al. (2020) · JMIR Medical Informatics · doi:10.2196/15931 · Cited by 109
Artificial intelligence-enabled electrocardiography from scientific research to clinical application
Lin, C.-S., Liu, W.-T., Chen, Y.-H., Lin, S.-H., & Lin, C. (2025) · EMBO Molecular Medicine · doi:10.1038/s44321-025-00351-y · Cited by 15
Metadata
- Authors
- Zabihi, M., Bahrami Rad, A., Katsaggelos, A. K., Kiranyaz, S., Narkilahti, S., & Gabbouj, M.
- Venue
- Computing in Cardiology Conference (CinC)
- Publisher
- Computing in Cardiology
- Published
- 2017-09-14
- Volume
- 44
- ISSN
- 2325-887X (ISSN-L)
- OpenAlex
- W2795153139
- Cited by
- 158
- References
- 3
- FWCI
- 33.80
- Type
- conference paper
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Atrial Fibrillation in ECG Hand-held Devices Using a Random Forest Classifier. https://app.cochat.ai/papers/10.22489/cinc.2017.069-336
- The paper
- Zabihi, M., Bahrami Rad, A., Katsaggelos, A. K., Kiranyaz, S., Narkilahti, S., & Gabbouj, M. (2017). Detection of Atrial Fibrillation in ECG Hand-held Devices Using a Random Forest Classifier. Computing in Cardiology Conference (CinC). https://doi.org/10.22489/cinc.2017.069-336
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.