Abstract

Bioassays with a quantitative response showing a sigmoid log-dose relationship can be analysed by fitting a non-linear dose-response model directly to the data. It is demonstrated that the four-parameter logistic model, previously applied to immunoassay (Healy 1972), is applicable to the free fat cell bioassay of insulin (Moody, Stan, Stan and Gliemann 1974). It is shown that the standard slope ratio and parallel line models for bioassay can be considered as approximations to the logistic in the extreme dose regions, while the parallel line model can be expected to fit in the middle region. The full statistical analysis of the four-parameter logistic model applied to a general assay design is described. An APL computer program has been developed to facilitate the calculations, which include non-linear curve-fitting, tests of goodness of fit and parallelity, as well as point and interval estimates of the relative potency. Examples of free fat cell bioassays of insulin that have been analysed according to these methods are given. Efficient estimation of the potency calls for concentrating the doses in the region with the steepest slope of the dose-response curve. With respect to testing the parallelity and to allow for assay-to-assay variability and unpredictable potencies, it may be preferable to use an assay design with doses distributed over a wide range and to apply a dose-response model which, like the four-parameter logistic, is capable of fitting over the whole feasible dose range.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2307/2530598

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Volund, A.
Venue
Biometrics
Publisher
JSTOR
Published
1978-09
Volume
34
Issue
3
Pages
357
ISSN
0006-341X (ISSN-L)
OpenAlex
W2029437336
Cited by
125
References
0
FWCI
1.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.