Multiple Test Procedures for Dose Finding
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The problem of identifying the lowest dose level for which the mean response differs from that at the zero dose level is considered. A general framework for stepwise testing procedures that use contrasts among the dose level means is proposed. Using this framework, several new procedures are derived. These and some existing procedures, including that of Williams (1971, Biometrics 27, 103-117; 1972, Biometrics 28, 519-531), are compared analytically and by an extensive simulation study for the normal theory balanced one-way layout case. It is pointed out that the procedures based on the so-called step and basin contrasts proposed by Ruberg (1989, Journal of American Statistical Association 84, 816-822) have excessively high type I familywise error rates (FWEs) and, hence, they should not be used. Some findings of the simulation study are as follows: For monotone dose mean configurations, Williams' procedure and two step-down test procedures based on Helmert and linear contrasts offer the best performance. For nonmonotone dose mean configurations, the performance of Williams' procedure does degrade somewhat, but the other two procedures are still the best. For more complex designs, a simple step-down test procedure that uses any alpha-level tests (not necessarily t-tests) to compare each dose level with the zero dose level controls the FWE and is the only alternative available, but its power is rather low, especially under nonmonotone configurations. Step-up procedures are generally dominated by step-down procedures when the same contrasts are used although the differences are not great.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modified Sequentially Rejective Multiple Test Procedures
Shaffer, J. P. (1986) · Journal of the American Statistical Association · doi:10.1080/01621459.1986.10478341 · Cited by 806
Quantitative Risk Assessment for Developmental Toxicity
Ryan, L. (1992) · Biometrics · doi:10.2307/2532747 · Cited by 113 · cited 1×
“…studies, the conventional approach is to find the highest dose for which the response does not differ significantly from that at the zero dose (called the no observed adverse event level [NOAEL] dose; see Ryan, 1992) and apply an appropriate safety factor to it to arrive at a safe dose level.”
Background
Cited by
Ratziu, V., Harrison, S. A., Francque, S., Bedossa, P., Lehert, P., Serfaty, L., Romero-Gomez, M., Boursier, J., Abdelmalek, M., Caldwell, S., et al. (2016) · Gastroenterology · doi:10.1053/j.gastro.2016.01.038 · Cited by 1,035
“No multiplicity correction was needed due to step-down strategy.(22) For patients with liver biopsy unavailable at the end of treatment, a worst-case”
BackgroundCombining Multiple Comparisons and Modeling Techniques in Dose‐Response Studies
Bretz, F., Pinheiro, J. C., & Branson, M. (2005) · Biometrics · doi:10.1111/j.1541-0420.2005.00344.x · Cited by 398
Takashima, K., Matsunaga, N., Yoshimatsu, M., Hazeki, K., Kaisho, T., Uekata, M., Hazeki, O., Akira, S., Iizawa, Y., & Ii, M. (2009) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2009.00297.x · Cited by 246
Tauber, J., Davitt, W. F., Bokosky, J. E., Nichols, K. K., Yerxa, B. R., Schaberg, A. E., LaVange, L. M., Mills-Wilson, M. C., & Kellerman, D. J. (2004) · Cornea · doi:10.1097/01.ico.0000133993.14768.a9 · Cited by 168
“sons was handled by the use of a step-down procedure for hypothesis testing.(20) For each primary endpoint, the comparison between 2% diquafosol and placebo was first carried out, and”
MethodZieglmayer, P., Focke-Tejkl, M., Schmutz, R., Lemell, P., Zieglmayer, R., Weber, M., Kiss, R., Blatt, K., Valent, P., Stolz, F., et al. (2016) · EBioMedicine · doi:10.1016/j.ebiom.2016.08.022 · Cited by 138
Metadata
- Authors
- Tamhane, A. C., Hochberg, Y., & Dunnett, C. W.
- Venue
- Biometrics
- Publisher
- JSTOR
- Published
- 1996-03
- Volume
- 52
- Issue
- 1
- Pages
- 21
- ISSN
- 0006-341X (ISSN-L)
- OpenAlex
- W1981740138
- Cited by
- 184
- References
- 2
- FWCI
- 9.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiple Test Procedures for Dose Finding. https://app.cochat.ai/papers/10.2307/2533141
- The paper
- Tamhane, A. C., Hochberg, Y., & Dunnett, C. W. (1996). Multiple Test Procedures for Dose Finding. Biometrics. https://doi.org/10.2307/2533141
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.