Advanced Techniques in Biological Electron Microscopy
The DOI matches its Crossref record.
Abstract
Three-Dimensional Reconstruction of Nonperiodic Macromolecular Assemblies from Electron Micrographs.- 1 Introduction.- 1.1 General.- 1.2 The Three-Dimensional Structure as an Average.- 2 Methods for Obtaining Projection Data.- 2.1 What is Being Reconstructed?.- 2.2 Scanning of Projection Data.- 2.3 Hardware and Software for Electron Image Processing.- 2.4 Alignment of Projections.- 2.5 Methods for Obtaining Statistically Significant Projections.- 3 Methods of Three-Dimensional Reconstruction.- 3.1 Preliminaries.- 3.2 Some Existing Algorithms for Reconstruction.- 3.2.1 Real-Space Methods.- 3.2.2 Fourier Methods.- 3.3 Resolution of the Reconstructed Object.- 3.4 The Point Spread Function and the Effect of Angular Limitations.- 3.5 Conical Tilting Geometry.- 3.6 Experimental Data Collection Methods.- 3.6.1 Goniometer Tilting.- 3.6.2 Use of Multiple A Priori Orientations.- 3.6.3 Random Tilts of a Long, Quasi-Cylindrical Particle.- 3.6.4 Random In-Plane Rotations of a Particle Having a Fixed Orientation.- 3.7 Representation of Three-Dimensional Data.- 4 Experimental Results.- 4.1 Ribosome.- 4.2 Oxygen-Carrying Proteins: Hemocyanins and Hemoglobins of Invertebrates.- 4.3 Chromatin.- 4.4 Survey of Published Results.- 5 Conclusions.- Appendix: Some Important Definitions and Theorems.- A.1 The Two-Dimensional Fourier Transform.- A.2 Convolution.- A.3 Resolution in the Fourier Domain.- A.4 Low-Pass Filtration.- A.5 Correlation Functions.- A.6 The Projection Theorem.- References.- High Resolution Biological X-Ray Microanalysis of Diffusable Ions.- 1 Introduction.- 2 Principles of the Technique.- 3 Specimen Preparation.- 3.1 Introduction.- 3.2 Low Temperature Methods for AEM.- 3.3 Tissue Preparation.- 3.4 Rapid Freezing.- 3.5 Cryoultramicrotomy.- 3.6 Frozen Transfer.- 3.7 Freezing Drying.- 4 Quantitation.- 4.1 Theory of Quantitation of Biological Thin Samples.- 4.2 Errors in Quantitation.- 4.3 Mapping.- 5 Applications in the Analysis of Diffusable Ions.- 6 Conclusion.- References.- Metal Deposition by High-Energy Sputtering for High Magnification Electron Microscopy.- 1 Introduction.- 1.1 Increase of Surface Information.- 1.2 Background.- 1.2.1 Enhancement of Topographic Contrast.- 1.2.2 Increase of Contrast at High Magnification.- 1.2.3 High Resolution Replicas.- 1.2.4 Scanning Electron Microscopy.- 1.2.5 Visualization of Surface Fine Structures.- 1.3 Contrast Principles.- 1.4 Limiting Properties of Conventionally Used Metal Films.- 1.4.1 Metal Film Thickness.- 1.4.2 Particle Decoration.- 2 Methods.- 2.1 Microscopy.- 2.1.1 Specimens and Preparation.- 2.1.2 Instruments.- 2.1.3 Useful Magnifications.- 2.2 Metal Deposition Technique.- 2.2.1 High Vacuum Metal Deposition System.- 2.2.2 Geometric Factors for Metal Deposition.- 2.2.3 Film Thickness Measurements.- 3 Metal Deposition.- 3.1 Metal Film Formation.- 3.1.1 Phases of Film Growth.- 3.1.2 Nucleation.- 3.1.3 Film Growth from Nuclei.- 3.2 Low-Rate High-Energy Sputter Deposition.- 3.2.1 Energy Parameters.- 3.2.2 Low-Rate Deposition.- 3.3 Thin Continuous Film Production.- 3.3.1 Reduction of Decoration Effects.- 3.3.2 Reduction of Scattering.- 3.3.3 Reduction of Self-Shadowing.- 3.3.4 Reduction of Contamination.- 3.3.5 Critical Film Thickness.- 3.4 Coating Strategy.- 3.4.1 Surface Information.- 3.4.2 Rationales for Continuous Film Application.- 3.4.3 Choice of Coating Technique.- 3.4.4 Test Specimen.- 4 Conclusion.- References.- Computer Programs for Biological Stereology.- 1 Introduction.- 1.1 Stereology: An Overview.- 1.2 Biological Applications of Stereology.- 2 Point Counting Programs.- 2.1 Point Counting Stereology: An Overview.- 2.2 Hardware.- 2.3 Software.- 2.3.1 Experiment Design.- 2.3.2 Data Input.- 2.3.3 Data Management.- 2.3.4 Data Analysis.- 2.3.5 Data Output.- 3 Digitizing Programs.- 3.1 Digitizing Stereology: An Overview.- 3.2 Hardware.- 3.3 Software.- 3.3.1 Data Collected.- 3.3.2 Data Analysis.- 4 Special Purpose Stereology Programs.- 4.1 Size Frequency Distributions and Mean Caliper Diameters.- 4.1.1 Convex Structures.- 4.1.2 Nonconvex Structures.- 4.1.3 Oriented Structures.- 4.2 Sampling Analysis.- 4.3 Quantification of Freeze-Fracture Replicas.- 4.4 Pattern Analysis.- 5 Concluding Comments.- References.- A Guide to Fracture Label: Cytochemical Labeling of Freeze-Fractured Cells.- 1 Introduction.- 1.1 Freeze-Fracture: Membrane Splitting.- 1.2 Freeze Etching: Membrane Cytochemistry.- 1.3 Fracture Label: Freeze-Fracture Cytochemistry.- 2 Experimental Procedures.- 2.1 Main Steps.- 2.2 Preparation of Specimens.- 2.2.1 Fixation.- 2.2.2 Embedding in BSA.- 2.2.3 Impregnation.- 2.2.4 Freezing.- 2.2.5 The Sandwich Method.- 2.3 Freeze Fracture.- 2.3.1 Thin-Section Fracture Label (TS-FL).- 2.3.2 Critical Point Drying Fracture Label (CPD-FL).- 2.4 Thawing and Deglycerination.- 2.4.1 Thin-Section Fracture Label (TS-FL).- 2.4.2 Critical Point Drying Fracture Label (CPD-FL).- 2.5 Labeling.- 2.5.1 Detection of Concanavalin A Binding Sites.- 2.5.2 Detection of Wheat-Germ A
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dual-Axis Tomography: An Approach with Alignment Methods That Preserve Resolution
Mastronarde, D. N. (1997) · Journal of Structural Biology · doi:10.1006/jsbi.1997.3919 · Cited by 1,057
Separation of mouse spermatogenic cells by sedimentation velocity
Romrell, L. J., Bellvé, A. R., & Fawcett, D. W. (1976) · Developmental Biology · doi:10.1016/0012-1606(76)90262-1 · Cited by 495
Dunn, W. A., Hubbard, A. L., & Aronson, N. N. (1980) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)70726-1 · Cited by 452
Three-Dimensional Reconstruction from Projections: A Review of Algorithms
Gordon, R., & Herman, G. (1974) · International Review of Cytology · doi:10.1016/s0074-7696(08)60925-0 · Cited by 335
SPIDER—A modular software system for electron image processing
Frank, J., Shimkin, B., & Dowse, H. (1981) · Ultramicroscopy · doi:10.1016/s0304-3991(81)80221-5 · Cited by 282
Metadata
- Authors
- Maugel, T. K., & Koehler, J. K.
- Venue
- Transactions of the American Microscopical Society
- Publisher
- JSTOR
- Published
- 1974-04
- Volume
- 93
- Issue
- 2
- Pages
- 283
- ISSN
- 0003-0023 (ISSN-L)
- OpenAlex
- W2168243643
- Cited by
- 277
- References
- 0
- FWCI
- 18.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advanced Techniques in Biological Electron Microscopy. https://app.cochat.ai/papers/10.2307/3225305
- The paper
- Maugel, T. K., & Koehler, J. K. (1974). Advanced Techniques in Biological Electron Microscopy. Transactions of the American Microscopical Society. https://doi.org/10.2307/3225305
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.