The DOI matches its Crossref record.
Renal Damage in the Mouse: The Response to Very Small Doses per Fraction
Abstract
Experiments were undertaken to study the effect on the mouse kidney of repeated X-ray doses in the range 0.2 to 1.6 Gy per fraction and neutron doses in the range 0.05 to 0.25 Gy per fraction. A top-up design of experiment was used, so that additional graded doses of d(4)-Be neutrons (EN = 2.3 MeV) were given to bring the subthreshold damage produced by these treatments into the measurable range. This approach avoided the necessity to use a large number of fractions to study low doses per fraction. Renal damage was assessed using three methods: 51Cr-EDTA clearance, urine output, and hematocrit at 16-50 weeks postirradiation. The dose-response curves obtained were resolved best at 29 weeks. However, the results were also examined by fitting second-order polynomials to the data for response versus time postirradiation and using interpolated values from these functions at 29 weeks to construct dose-response curves. This method reduced slightly the variation in the dose-response data, but the interrelationship between the dose-response curves remained the same. The data were used to test the linear-quadratic (LQ) description of the underlying X-ray dose-fractionation relationship. The model fits well down to X-ray doses per fraction of approximately 1 Gy, but lower X-ray doses were more effective per gray than predicted by LQ, as seen previously in skin [M. C. Joiner et al., Int. J. Radiat. Biol. 49, 565-580 (1986)]. This increased X-ray effectiveness and deviation from LQ are reflected directly in a decrease in the RBE of d(4)-Be neutrons relative to X-rays at low doses, since the underlying response to these neutrons is linear in this low-dose region. The RBE decreases from 9.9 to 4.7 as the X-ray dose per fraction is reduced below 0.8 Gy to 0.2 Gy, reflecting an increase in X-ray effectiveness by a factor of 2.1. A model is discussed which attempts to explain this behavior at low doses per fraction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The linear-quadratic formula and progress in fractionated radiotherapy
Fowler, J. F. (1989) · The British Journal of Radiology · doi:10.1259/0007-1285-62-740-679 · Cited by 2,252
Stewart, F. A., Akleyev, A. V., Hauer-Jensen, M., Hendry, J. H., Kleiman, N. J., MacVittie, T. J., Aleman, B. M., Edgar, A. B., Mabuchi, K., Muirhead, C. R., et al. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.02.001 · Cited by 1,604
Low-dose hypersensitivity: current status and possible mechanisms
Joiner, M. C., Marples, B., Lambin, P., Short, S. C., & Turesson, I. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)01471-1 · Cited by 570
Self-citationLittle, M. P., Wakeford, R., Tawn, E. J., Bouffler, S. D., & Berrington de Gonzalez, A. (2009) · Radiology · doi:10.1148/radiol.2511081686 · Cited by 353
Marples, B., & Joiner, M. C. (1993) · Radiation Research · doi:10.2307/3578255 · Cited by 296
Self-citation
Metadata
- Authors
- Joiner, M. C., & Johns, H.
- Venue
- Radiation Research
- Publisher
- JSTOR
- Published
- 1988-05
- Volume
- 114
- Issue
- 2
- Pages
- 385
- ISSN
- 0033-7587 (ISSN-L)
- OpenAlex
- W2020046224
- Cited by
- 167
- References
- 0
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Renal Damage in the Mouse: The Response to Very Small Doses per Fraction. https://app.cochat.ai/papers/10.2307/3577233
- The paper
- Joiner, M. C., & Johns, H. (1988). Renal Damage in the Mouse: The Response to Very Small Doses per Fraction. Radiation Research. https://doi.org/10.2307/3577233
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.