CoChat

Methods for the Quantification of DNA Double-Strand Breaks Determined from the Distribution of DNA Fragment Sizes Measured by Pulsed-Field Gel Electrophoresis

Cedervall, B., Wong, R., Albright, N., Dynlacht, J., Lambin, P., Dewey, W. C. · 1995 · Radiation Research
Cited by 94

The DOI matches its Crossref record.

Abstract

Different methods were used for evaluating data for DNA double-strand breaks (DSBs), as obtained by pulsed-field gel electrophoresis (PFGE) after X irradiation of Chinese hamster ovary cells. A total of 60 data points in the dose range of 0 to 116 Gy, along with repair data for 30 and 60 Gy, were analyzed by four methods: (1) percentage of DNA released from the plug, (2) specific size markers (percentage of DNA less than specific sizes, (3) fragment size distributions and (4) shape of the molecular weight (M) distributions. With the last method, both the slope and the intercept of the logarithm of the amount of radioactive DNA/delta M/M plotted as a function of M were used for calculating DSBs/100 Mbp. The slope and the intercept analyses differ in that the former is relatively independent of DNA trapped in the agarose plugs, i.e. cannot be released by doses of 100-150 Gy, whereas the intercept is dependent on the percentage of DNA trapped. Also, calculations of DSBs/100 Mbp for methods 1, 2 and 3 depend on the amount of DNA trapped in the plug. However, the slope method is unreliable for doses below about 20 Gy, and the scatter of data points is much greater than that obtained by the intercept method and by methods 1, 2 and 3. Therefore, the fragment size distribution and the specific size marker methods give the most consistent results, with 0.49 +/- 0.03 (95% CI) (DSBs/100 Mbp)/Gy. With the specific size marker method, however, care must be taken in selection of size markers in relation to the levels of DSBs of interest. Assuming randomly distributed DSBs, all four methods gave essentially the same results; i.e., the dose response was linear with a calculated level of 0.5-0.6 (DSBs/100 Mbp)/Gy, which is the same as 0.47-0.62 determined previously by calibrating with 125IdU.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2307/3578920

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 94

Metadata

Authors
Cedervall, B., Wong, R., Albright, N., Dynlacht, J., Lambin, P., & Dewey, W. C.
Venue
Radiation Research
Publisher
JSTOR
Published
1995-07
Volume
143
Issue
1
Pages
8
ISSN
0033-7587 (ISSN-L)
OpenAlex
W1976108918
Cited by
94
References
0
FWCI
6.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Methods for the Quantification of DNA Double-Strand Breaks Determined from the Distribution of DNA Fragment Sizes Measured by Pulsed-Field Gel Electrophoresis. https://app.cochat.ai/papers/10.2307/3578920
The paper
Cedervall, B., Wong, R., Albright, N., Dynlacht, J., Lambin, P., & Dewey, W. C. (1995). Methods for the Quantification of DNA Double-Strand Breaks Determined from the Distribution of DNA Fragment Sizes Measured by Pulsed-Field Gel Electrophoresis. Radiation Research. https://doi.org/10.2307/3578920

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.