The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Monte Carlo Simulation of the Production of Short DNA Fragments by Low-Linear Energy Transfer Radiation Using Higher-Order DNA Models
Abstract
A realistic DNA target model has been developed and implemented in the biophysical simulation code PARTRAC. It describes five levels of the B-DNA structure (nucleotides, DNA helices, nucleosomes, chromatin fiber structure and chromatin fiber loops) on an atomic level for the whole genome inside a mammalian cell nucleus. The model is capable of describing regular solenoidal, crossed-linker or zigzag structures as well as repeating stochastic arrangements of nucleosomes in the chromatin fiber. Electron tracks resulting from monoenergetic electrons with energies up to 100 keV and from 220 kVp X rays, starting at random positions in the cell, were superimposed on four DNA target models with different chromatin fiber structures. The yields of SSBs, DSBs and short single- and double-stranded DNA fragments were determined from spatial coincidences with strand atoms. Two parameters of the model-the energy necessary to create an SSB and the distance between two breaks that would be scored as a DSB-were adapted to equate simulated and measured strand break yields after X irradiation of human fibroblast cells. The integral fractions of short single- and double-stranded fragments were rather similar for all condensed chromatin fiber structures; they agreed with experimental data for DNA fragments below 2 kbp. The simulated fragment size distributions in the range from 0.1 to 1.5 kbp reflected the fiber structure irrespective of strandedness or electron energy. The distributions using a stochastic arrangement of nucleosomes in the chromatin fiber were found to be in better accordance with experimental data than those obtained with regular fiber structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Track structure analysis of ultrasoft X-rays compared to high- and low-LET radiations
Goodhead, D. T., & Nikjoo, H. (1989) · International Journal of Radiation Biology · doi:10.1080/09553008914550571 · Cited by 223
Cited by
Formation of Clustered DNA Damage after High-LET Irradiation: A Review
HADA, M., & GEORGAKILAS, A. G. (2008) · Journal of Radiation Research · doi:10.1269/jrr.07123 · Cited by 449
Friedland, W., Dingfelder, M., Kundrát, P., & Jacob, P. (2011) · Mutation Research - Fundamental and Molecular Mechanisms of Mutagenesis · doi:10.1016/j.mrfmmm.2011.01.003 · Cited by 386
Self-citationSimulation of DNA Damage after Proton Irradiation
Friedland, W., Jacob, P., Bernhardt, P., Paretzke, H. G., & Dingfelder, M. (2003) · Radiation Research · doi:10.1667/0033-7587(2003)159[0401:soddap]2.0.co;2 · Cited by 264
Self-citationAlloni, D., Campa, A., Friedland, W., Mariotti, L., & Ottolenghi, A. (2012) · International Journal of Radiation Biology · doi:10.3109/09553002.2011.627976 · Cited by 58
Self-citationOttolenghi, A., Ballarini, F., & Merzagora, M. (1999) · Radiation and Environmental Biophysics · doi:10.1007/s004110050132 · Cited by 36
Metadata
- Authors
- Friedland, W., Jacob, P., Paretzke, H. G., & Stork, T.
- Venue
- Radiation Research
- Publisher
- JSTOR
- Published
- 1998-08
- Volume
- 150
- Issue
- 2
- Pages
- 170
- ISSN
- 0033-7587 (ISSN-L)
- OpenAlex
- W2316709185
- Cited by
- 171
- References
- 1
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monte Carlo Simulation of the Production of Short DNA Fragments by Low-Linear Energy Transfer Radiation Using Higher-Order DNA Models. https://app.cochat.ai/papers/10.2307/3579852
- The paper
- Friedland, W., Jacob, P., Paretzke, H. G., & Stork, T. (1998). Monte Carlo Simulation of the Production of Short DNA Fragments by Low-Linear Energy Transfer Radiation Using Higher-Order DNA Models. Radiation Research. https://doi.org/10.2307/3579852
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.