Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 232

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Automated identification of cephalometric landmarks: Part 1—Comparisons between the latest deep-learning methods YOLOV3 and SSD

Open access
Park, Ji-Hoon, Hwang, Hye-Won, Moon, Jun-Ho, Yu, Youngsung, Kim, Hansuk, Her, Soo-Bok, Srinivasan, Girish, Aljanabi, Mohammed Noori A., Donatelli, Richard E., Lee, Shin-Jae · 2019 · The Angle Orthodontist

Abstract

Objective: To compare the accuracy and computational efficiency of two of the latest deep-learning algorithms for automatic identification of cephalometric landmarks. Materials and Methods: A total of 1028 cephalometric radiographic images were selected as learning data that trained You-Only-Look-Once version 3 (YOLOv3) and Single Shot Multibox Detector (SSD) methods. The number of target labeling was 80 landmarks. After the deep-learning process, the algorithms were tested using a new test data set composed of 283 images. Accuracy was determined by measuring the point-to-point error and success detection rate and was visualized by drawing scattergrams. The computational time of both algorithms was also recorded. Results: The YOLOv3 algorithm outperformed SSD in accuracy for 38 of 80 landmarks. The other 42 of 80 landmarks did not show a statistically significant difference between YOLOv3 and SSD. Error plots of YOLOv3 showed not only a smaller error range but also a more isotropic tendency. The mean computational time spent per image was 0.05 seconds and 2.89 seconds for YOLOv3 and SSD, respectively. YOLOv3 showed approximately 5% higher accuracy compared with the top benchmarks in the literature. Conclusions: Between the two latest deep-learning methods applied, YOLOv3 seemed to be more promising as a fully automated cephalometric landmark identification system for use in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2319/022019-127.1

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 232

Metadata

Authors
Park, J.-H., Hwang, H.-W., Moon, J.-H., Yu, Y., Kim, H., Her, S.-B., Srinivasan, G., Aljanabi, M. N. A., Donatelli, R. E., & Lee, S.-J.
Venue
The Angle Orthodontist
Published
2019-07-08
Volume
89
Issue
6
Pages
903-909
ISSN
  • 0003-3219 (ISSN-L)
  • 1945-7103
OpenAlex
W2962455611
Cited by
232
References
4
FWCI
19.69
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated identification of cephalometric landmarks: Part 1—Comparisons between the latest deep-learning methods YOLOV3 and SSD. https://app.cochat.ai/papers/10.2319/022019-127.1
The paper
Park, J.-H., Hwang, H.-W., Moon, J.-H., Yu, Y., Kim, H., Her, S.-B., Srinivasan, G., Aljanabi, M. N. A., Donatelli, R. E., & Lee, S.-J. (2019). Automated identification of cephalometric landmarks: Part 1—Comparisons between the latest deep-learning methods YOLOV3 and SSD. The Angle Orthodontist. https://doi.org/10.2319/022019-127.1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.