Cited by 3Diabetes Management and ResearchDiabetes Management and EducationIntravenous Infusion Technology and Safety

696-P: Insulin Pump Infusion Set Failure (IPISF) Management: T1D Exchange Survey

WILCOX, JOHN H., GRAY, JOHN C., COOPER, NICHOLAS R., BLANCO, LUIS E., KELLEHER, RYAN, VANENGELEN, LISANNE M., LAL, RAYHAN·2021·Diabetes

Abstract

Aim: To identify IPISF occurrence and troubleshooting methods, determine habits and perceptions of diabetes technology use, and assess the history and satisfaction of education in those who utilize CSII. Methods: A 57-item online survey was constructed and included demographic questions, assessment with Likert scales, and open-ended questions regarding infusion sets. Participants were recruited via the T1D Exchange online community database. Statistical analysis was performed using R and JMP. Results: A total of 715 individuals were surveyed including 639 people with diabetes (PwD) and 76 caretakers among 49 states and territories from 09/2020 - 11/2020. Demographics: PwD age 51.6±15.1 years, caretaker age 46.1±7.6 years (dependent PwD age 15.2±11.2 year), 99.6% type 1 diabetes, 69% female, 92% white, CSII use for 14.1±8.5 years, 44% use AID, HbA1c 6.8±0.97%, TIR 72.3±16.1%, TIR 3 days. 97% of participants experience IPISF with 41% reporting ≥1 IPISF/month. Following IPISF, participants administered correction boluses using their pump with (41%) and without (44%) changing their failed infusion set. 61% of subjects had not received IPISF education in over a year and 19% had never received IPISF education. For users who experience ≥1 IPISF/month, hyperglycemia and related symptoms were more likely to alert users of IPISF than pump alarms (n=259, p=0.0355). Respondents with ≥1 IPISF/month were also more likely to both feel burned out by their diabetes technology (p<0.001) and wa…

Integrity signals

Registry

Crossref · 10.2337/db21-696-p

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Alarm systems are often inadequate; 66.3% of users detected infusion set failures through hyperglycemic symptoms, while only 25% were alerted by pump alarms.

    “Alarm systems are often inadequate, as evidenced by a survey where 66.3% of users detected infusion set failures through hyperglycemic symptoms, while only 25% were alerted by pump alarms.24”
  • Insulin infusion set failures are common among individuals using insulin pump therapy.

    “However, insulin infusion set (IIS) failures are common among individuals using insulin pump therapy.3–5”

Cited by

Sorted by citations

Authors
WILCOX, J. H., GRAY, J. C., COOPER, N. R., BLANCO, L. E., KELLEHER, R., VANENGELEN, L. M., & LAL, R.
Affiliations
Memphis, TN, Stanford, CA
Venue
Diabetes
Published
2021-06-01
Volume
70
Issue
Supplement_1
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W3176941735
Cited by
3
References
0
Citations by year
2026: 1 · 2024: 2
FWCI
0.37
Type
journal article
Language
en
Open access
closed
Locations
Diabetes (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
Keywords
insulin pump therapy, type 1 diabetes, diabetes technology use, diabetes education, caregiver burden, diabetes management

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review