CoChat

980-P: Continuous Glucose Monitor Improves Glycemic Control in Youth-Onset Type 2 Diabetes

CHANG, NANCY T., SMITH, JOSEPHINE ANDREA, CHAO, LILY · 2022 · Diabetes
Cited by 1

The DOI matches its Crossref record.

Abstract

Background: Youth with type 2 diabetes (T2D) develop early treatment failure. Most patients do not self-monitor blood glucose (SMBG) levels at recommended frequency. Continuous glucose monitor (CGM) has been shown to improve glycemic control in pediatric T1D and adult T2D. Its feasibility and efficacy in youth-onset T2D is unknown. Hypothesis: Participants who wear the CGM >85% of the time will lower their HbA1c by at least 0.5%. Methods: T2D patients prescribed insulin were eligible to participate if their HbA1c was at least 8%. Participants were randomized to 3-months of SMBG or Dexcom G6 CGM, followed by 3 months of washout (SMBG) and 3-month crossover to the other treatment arm. Participants and their clinical providers agreed to not start new diabetes medications but could adjust insulin dosing or add on rapid-acting insulin if HbA1c >9% at follow-up. A nurse care manager provided coaching for the first 30 days of CGM use. The CGM-SAT satisfaction survey was administered at the end of CGM wear. Student t-test and Fisher’s exact test were used to compare differences in continuous and categorical variables between groups, respectively. A 5% level of significance was used. Results: out of 14 participants completed the study. Our cohort was 55% female. At enrollment, mean age was 17.4±2.0 years, diagnosis duration was 4.0±2.8 years, and HbA1c was 11.5±2.5%. The percentage of days with CGM data trended from 89% down to 73% between the 1st and 3rd month of CGM use (not statistically significant) . CGM use lowered HbA1c by 2.8% for the cohort (SMBG: -0.1%, CGM: -3.1%, P=0.005) and by 3.8% for those who wore the CGM >85% of the time (P=0.01) . The mean CGM item score was 3.7 ± 0.5, comparable to prior results reported in T1D youth. Conclusion: Consistent CGM use improves glycemic control in youth-onset type 2 diabetes in this pilot study. Not all patients experienced an improvement in HbA1c. A larger study is warranted to validate the findings of this study and to identify patients who are most likely to benefit from CGM use. Disclosure: N.T.Chang: None. J.Smith: None. L.Chao: None. Funding: Dexcom

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/db22-980-p

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
CHANG, N. T., SMITH, J. A., & CHAO, L.
Affiliations
Los Angeles, CA
Venue
Diabetes
Published
2022-06-01
Volume
71
Issue
Supplement_1
ISSN
0012-1797
Cited by
0
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.