CoChat

Assessment of Patients’ and Physicians’ Compliance to an ACE Inhibitor Treatment Based on Urinary N-Acetyl Ser-Asp-Lys-Pro Determination in the Noninsulin-Dependent Diabetes, Hypertension, Microalbuminuria, Proteinuria, Cardiovascular Events, and Ramipril (DIABHYCAR) Study

Open access
Azizi, Michel, Ménard, Joël, Peyrard, Séverine, Lièvre, Michel, Marre, Michel, Chatellier, Gilles · 2006 · Diabetes Care
Cited by 38

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVE—The purpose of this study was to assess patients’ and physicians’ compliance with ACE inhibitor treatment, by measuring an endogenous biomarker of ACE inhibition, urinary N-acetyl-Ser-Asp-Lys-Pro (AcSDKP), in the Noninsulin-Dependent Diabetes, Hypertension, Microalbuminuria, Proteinuria, Cardiovascular Events, and Ramipril (DIABHYCAR) trial, which compared ramipril (1.25 mg o.d.) with placebo in 4,912 patients with type 2 diabetes and microalbuminuria/proteinuria. RESEARCH DESIGN AND METHODS—The urine AcSDKP-to-creatinine ratio was measured blind to treatment in all participants who completed follow-up and provided spot urine samples (n = 1,871). RESULTS—The median urinary AcSDKP-to-creatinine ratio was six times higher for ramipril than for placebo. Urinary AcSDKP-to-creatinine ratios displayed a bimodal distribution in both groups, with a very large intergroup overlap. Based on cluster analysis, we defined truly adherent ramipril patients as those with a ratio ≥4 nmol/mmol and truly adherent placebo patients as those with a ratio <4 nmol/mmol. After excluding patients withdrawing prematurely from the study or known to have used a nonstudy ACE inhibitor, 27.3% of the 597 ramipril patients had ratios <4, indicating poor compliance, and 9.7% of the 621 placebo patients had ratios ≥4, indicating intake of a nonstudy ACE inhibitor. Correcting for compliance by using AcSDKP-guided analysis affected surrogate outcome results (decrease in systolic blood pressure and urinary albumin excretion) only slightly. CONCLUSIONS—The systematic use of spot urinary AcSDKP determination facilitated the detection of defects in compliance with ACE inhibitor treatment in both patients and physicians. Urinary AcSDKP measurement could be a useful biomarker for assessing compliance with ACE inhibition in the routine care of diabetic patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc06-0255

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 38

Metadata

Authors
Azizi, M., Ménard, J., Peyrard, S., Lièvre, M., Marre, M., & Chatellier, G.
Venue
Diabetes Care
Published
2006-06-01
Volume
29
Issue
6
Pages
1331-1336
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2104575535
Cited by
38
References
4
FWCI
0.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of Patients’ and Physicians’ Compliance to an ACE Inhibitor Treatment Based on Urinary N-Acetyl Ser-Asp-Lys-Pro Determination in the Noninsulin-Dependent Diabetes, Hypertension, Microalbuminuria, Proteinuria, Cardiovascular Events, and Ramipril (DIABHYCAR) Study. https://app.cochat.ai/papers/10.2337/dc06-0255
The paper
Azizi, M., Ménard, J., Peyrard, S., Lièvre, M., Marre, M., & Chatellier, G. (2006). Assessment of Patients’ and Physicians’ Compliance to an ACE Inhibitor Treatment Based on Urinary N-Acetyl Ser-Asp-Lys-Pro Determination in the Noninsulin-Dependent Diabetes, Hypertension, Microalbuminuria, Proteinuria, Cardiovascular Events, and Ramipril (DIABHYCAR) Study. Diabetes Care. https://doi.org/10.2337/dc06-0255

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.