Comparison of Three Protocols for Tight Glycemic Control in Cardiac Surgery Patients
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We performed a randomized trial to compare three insulin-titration protocols for tight glycemic control (TGC) in a surgical intensive care unit: an absolute glucose (Matias) protocol, a relative glucose change (Bath) protocol, and an enhanced model predictive control (eMPC) algorithm. RESEARCH DESIGN AND METHODS: A total of 120 consecutive patients after cardiac surgery were randomly assigned to the three protocols with a target glycemia range from 4.4 to 6.1 mmol/l. Intravenous insulin was administered continuously or in combination with insulin boluses (Matias protocol). Blood glucose was measured in 1- to 4-h intervals as requested by the protocols. RESULTS: The eMPC algorithm gave the best performance as assessed by time to target (8.8 ± 2.2 vs. 10.9 ± 1.0 vs. 12.3 ± 1.9 h; eMPC vs. Matias vs. Bath, respectively; P < 0.05), average blood glucose after reaching the target (5.2 ± 0.1 vs. 6.2 ± 0.1 vs. 5.8 ± 0.1 mmol/l; P < 0.01), time in target (62.8 ± 4.4 vs. 48.4 ± 3.28 vs. 55.5 ± 3.2%; P < 0.05), time in hyperglycemia >8.3 mmol/l (1.3 ± 1.2 vs. 12.8 ± 2.2 vs. 6.5 ± 2.0%; P < 0.05), and sampling interval (2.3 ± 0.1 vs. 2.1 ± 0.1 vs. 1.8 ± 0.1 h; P < 0.05). However, time in hypoglycemia risk range (2.9–4.3 mmol/l) in the eMPC group was the longest (22.2 ± 1.9 vs. 10.9 ± 1.5 vs. 13.1 ± 1.6; P < 0.05). No severe hypoglycemic episode (<2.3 mmol/l) occurred in the eMPC group compared with one in the Matias group and two in the Bath group. CONCLUSIONS: The eMPC algorithm provided the best TGC without increasing the risk of severe hypoglycemia while requiring the fewest glucose measurements. Overall, all protocols were safe and effective in the maintenance of TGC in cardiac surgery patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive insulin therapy and pentastarch resuscitation in severe sepsis
Brunkhorst, F. M., Engel, C., Bloos, F., Meier-Hellmann, A., Ragaller, M., Weiler, N., Moerer, O., Gruendling, M., Oppert, M., Grond, S., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa070716 · Cited by 2,921 · cited 2×
“It is possible that insufficient time for insulin protocol implementation and the lack of previous experiences with TGC markedly influenced the outcomes of both studies (7,9,20,21).”
ResultFurnary, A. P., Gao, G., Grunkemeier, G. L., Wu, Y., Zerr, K. J., Bookin, S. O., Floten, H. S., & Starr, A. (2003) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2003.181 · Cited by 1,130 · cited 1×
“Other studies confirmed these findings, particularly in cardiac surgery patients [2-5] while others questioned safety and universality of beneficial effect of tight glycemic control (TGC) in different subgroups of critically ill patients [6-9].”
ResultTight glycaemic control by an automated algorithm with time-variant sampling in medical icu patients
Pachler, C., Plank, J., Weinhandl, H., Chassin, L. J., Wilinska, M. E., Kulnik, R., Kaufmann, P., Smolle, K.-H., Pilger, E., Pieber, T. R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1033-8 · Cited by 82 · cited 1×
“We performed a monocenter randomized trial and compared a protocol based on the absolute glucose value, the Matias protocol (15,17); a protocol based on the relative glucose change, the Bath protocol (19); and a computer-based model predictive control algorithm with variable sampling rate (eMPC) (16) developed within…”
MethodSelf-citation
Cited by
Jacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
Hemmingsen, B., Lund, S. S., Gluud, C., Vaag, A., Almdal, T., Hemmingsen, C., & Wetterslev, J. (2011) · BMJ · doi:10.1136/bmj.d6898 · Cited by 386
Hemmingsen, B., Lund, S. S., Gluud, C., Vaag, A., Almdal, T. P., & Wetterslev, J. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008143.pub4 · Cited by 291
Computerized advice on drug dosage to improve prescribing practice
Durieux, P., Trinquart, L., Colombet, I., Niès, J., Walton, R., Rajeswaran, A., Rège-Walther, M., Harvey, E., & Burnand, B. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002894.pub2 · Cited by 253
Hemmingsen, B., Lund, S. S., Gluud, C., Vaag, A., Almdal, T. P., & Wetterslev, J. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008143.pub3 · Cited by 203
Retracted
Metadata
- Authors
- Blaha, J., Kopecky, P., Matias, M., Hovorka, R., Kunstyr, J., Kotulak, T., Lips, M., Rubes, D., Stritesky, M., Lindner, J., Semrad, M., & Haluzik, M.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2009-02-05
- Volume
- 32
- Issue
- 5
- Pages
- 757-761
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2121295599
- Cited by
- 98
- References
- 3
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.