Measurement of Hemoglobin A1c
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Evaluation of glycemia is used for the diagnosis and management of patients with diabetes. Glucose and hemoglobin A1c (HbA1c) provide complementary information and both are used to assess an individual’s glycemic status. The concentration of glucose in the blood indicates the subject’s glycemia at the time of blood sampling. However, blood glucose concentrations are modified by numerous factors, ranging from food ingestion and exercise to stress and medication (1). By contrast, the concentration of HbA1c in the blood reflects the average glucose over the preceding 8–12 weeks. Thus, HbA1c provides an additional criterion for assessing glucose control that is free of the wide diurnal fluctuations that occur with blood glucose. HbA1c has several additional attributes, which render it valuable in the setting of diabetes. These include, but are not limited to, the following: the subject does not need to be fasting, blood can be sampled any time of the day, the sample is stable, and there is very little biological variability (1). These factors, in conjunction with the documentation that HbA1c predicts the development of microvascular (2,3) and macrovascular (4) complications of diabetes, have led to the widespread adoption of HbA1c as integral to the management of patients with diabetes. Guidelines from several prominent clinical organizations recommend that HbA1c be measured at regular intervals in all patients with diabetes (5,6). The quality of analytical methods for HbA1c initially lagged considerably behind the evidence of its clinical value. Early assays lacked standardization, substantially limiting the use of HbA1c in patient care. Considerable effort was invested to effect standardization, with schemes developed in the 1990s in Japan (7), Sweden (8), and the U.S. (9). All HbA1c results were reported as a percentage of hemoglobin. The subsequent …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stratton, I. M. (2000) · BMJ · doi:10.1136/bmj.321.7258.405 · Cited by 9,059
10-year follow-up of intensive glucose control in type 2 diabetes
Holman, R. R., Paul, S. K., Bethel, M. A., Matthews, D. R., & Neil, H. A. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806470 · Cited by 7,751 · cited 12×
“The goal of theNGSP is to standardize glycated hemoglobin test results to those of the DCCT and UKPDS, which established direct relationships between HbA1c concentrations and outcome risks Table 2dSpecies of modified HbA Name Site Modification A1a1 NH2 terminus of the b-chain Fructose 1,6-diphosphate A1a2 NH2 terminus…”
BackgroundInfluentialIntensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Standards of Medical Care in Diabetes—2012
(2012) · Diabetes Care · doi:10.2337/dc12-s011 · Cited by 2,240
Translating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
The Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301
Global guideline for type 2 diabetes
(2014) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2012.10.001 · Cited by 1,064
Hoelzel, W., Weykamp, C., Jeppsson, J.-O., Miedema, K., Barr, J. R., Goodall, I., Hoshino, T., John, W. G., Kobold, U., Little, R., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.024802 · Cited by 690
Approved IFCC reference method for the measurement of HbA1c in human blood
Jeppsson, J.-O., Kobold, U., Barr, J., Finke, A., Hoelzel, W., Hoshino, T., Miedema, K., Mosca, A., Mauri, P., Paroni, R., et al. (2002) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2002.016 · Cited by 655
Goldstein, D. E., Little, R. R., Lorenz, R. A., Malone, J. I., Nathan, D., Peterson, C. M., & Sacks, D. B. (2004) · Diabetes Care · doi:10.2337/diacare.27.7.1761 · Cited by 625 · cited 1×
“The ADA recommends that laboratories use only HbA1c assays that are certified by NGSP as traceable to the DCCT reference (33).”
MethodSelf-citation
Cited by
Cheng, A. Y. Y. (2013) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2013.01.009 · Cited by 728
Pitfalls in Hemoglobin A1c Measurement: When Results may be Misleading
Radin, M. S. (2014) · Journal of General Internal Medicine · doi:10.1007/s11606-013-2595-x · Cited by 361
Polypharmacy in the Aging Patient: A Review of Glycemic Control in Older Adults With Type 2 Diabetes
Lipska, K. J., Krumholz, H., Soones, T., & Lee, S. J. (2016) · JAMA · doi:10.1001/jama.2016.0299 · Cited by 309
Berard, L. D., Siemens, R., & Woo, V. (2018) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2017.10.007 · Cited by 69
Metadata
- Authors
- Sacks, D. B.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2012-11-14
- Volume
- 35
- Issue
- 12
- Pages
- 2674-2680
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2109003847
- Cited by
- 124
- References
- 14
- FWCI
- 7.93
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of Hemoglobin A1c. https://app.cochat.ai/papers/10.2337/dc12-1348
- The paper
- Sacks, D. B. (2012). Measurement of Hemoglobin A1c. Diabetes Care. https://doi.org/10.2337/dc12-1348
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.