Feasibility of Outpatient 24-Hour Closed-Loop Insulin Delivery
Open accessThe DOI matches its Crossref record.
Abstract
Studies using outpatient closed-loop insulin delivery for type 1 diabetes have recently been published (1–5). We conducted a 5-day outpatient feasibility study comparing hybrid closed-loop (HCL) to sensor-augmented pump therapy with low-glucose suspend (SAPT + LGS) in eight patients with type 1 diabetes using an open-label randomized crossover trial design (ACTRN12614001005640). We used the Medtronic HCL system: MiniMed insulin pump, MiniMed Enlite II glucose sensor, MiniMed MiniLink REAL-time sensor, MiniMed Translator, and an Android mobile device with the algorithm (proportional integrative derivate with insulin feedback and additional safety parameters—primarily being an upper limit of allowable insulin delivery). Multiple algorithm parameters were individualized according to total daily insulin requirements in the preceding 48 h. Meals were announced by entering a capillary glucose value and meal carbohydrate content, for which bolus insulin was delivered according to the patient’s unique carbohydrate ratio. The Android mobile device sent data via the Internet, …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Garg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585
Self-citationWeisman, A., Bai, J.-W., Cardinez, M., Kramer, C. K., & Perkins, B. A. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30167-5 · Cited by 463
Bekiari, E., Kitsios, K., Thabit, H., Tauschmann, M., Athanasiadou, E., Karagiannis, T., Haidich, A.-B., Hovorka, R., & Tsapas, A. (2018) · BMJ · doi:10.1136/bmj.k1310 · Cited by 437
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Liou, Y.-S., Yang, F.-Y., Chen, H.-Y., & Jong, G.-P. (2018) · PLOS ONE · doi:10.1371/journal.pone.0197245 · Cited by 75
Metadata
- Authors
- de Bock, M. I., Roy, A., Cooper, M. N., Dart, J. A., Berthold, C. L., Retterath, A. J., Freeman, K. E., Grosman, B., Kurtz, N., Kaufman, F., Jones, T. W., & Davis, E. A.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2015-08-27
- Volume
- 38
- Issue
- 11
- Pages
- e186-e187
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W1835735948
- Cited by
- 37
- References
- 0
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Feasibility of Outpatient 24-Hour Closed-Loop Insulin Delivery. https://app.cochat.ai/papers/10.2337/dc15-1047
- The paper
- de Bock, M. I., Roy, A., Cooper, M. N., Dart, J. A., Berthold, C. L., Retterath, A. J., Freeman, K. E., Grosman, B., Kurtz, N., Kaufman, F., Jones, T. W., & Davis, E. A. (2015). Feasibility of Outpatient 24-Hour Closed-Loop Insulin Delivery. Diabetes Care. https://doi.org/10.2337/dc15-1047
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.