Effect of Acetaminophen on CGM Glucose in an Outpatient Setting
Open accessThe DOI matches its Crossref record.
Abstract
Acetaminophen (paracetamol) interferes with continuous glucose monitor (CGM) sensing, resulting in falsely elevated CGM glucose values in both sensors currently approved by the U.S. Food and Drug Administration (FDA). In amperometric glucose biosensors, particularly those measuring hydrogen peroxide, acetaminophen’s phenolic moiety is oxidized at the sensing electrode, producing an electrochemical signal not related to glucose (1). Limited published data exist documenting the magnitude of the effect of acetaminophen on CGM glucose (2), especially in the outpatient setting with contemporary sensor technology. Currently, the FDA recommends that insulin dosing decisions are based on blood glucose (BG) meter values, not CGM glucose values. Given the common use of acetaminophen, its interference with CGM sensing has significant clinical implications for patients who use CGM. To better understand this effect, we performed an acetaminophen challenge as part of an outpatient study designed to investigate the potential challenges to closed-loop systems, which use CGM sensor …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Continuous glucose monitoring and metrics for clinical trials: an international consensus statement
Battelino, T., Alexander, C. M., Amiel, S. A., Arreaza-Rubin, G., Beck, R. W., Bergenstal, R. M., Buckingham, B. A., Carroll, J., Ceriello, A., Chow, E., et al. (2023) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00319-9 · Cited by 831
Self-citationOpportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
El-Khatib, F. H., Balliro, C., Hillard, M. A., Magyar, K. L., Ekhlaspour, L., Sinha, M., Mondesir, D., Esmaeili, A., Hartigan, C., Thompson, M. J., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(16)32567-3 · Cited by 254
Self-citationLorenz, C., Sandoval, W., & Mortellaro, M. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0028 · Cited by 80
Laffel, L. M., Aleppo, G., Buckingham, B. A., Forlenza, G. P., Rasbach, L. E., Tsalikian, E., Weinzimer, S. A., & Harris, D. R. (2017) · Journal of the Endocrine Society · doi:10.1210/js.2017-00389 · Cited by 79
“An important concern with rtCGM is falsely elevated glucose readings due to acetaminophen interference; trend arrows are most impacted during the onset and tailing off of acetaminophen use [34, 35].”
BackgroundInfluentialSelf-citation
Metadata
- Authors
- Maahs, D. M., DeSalvo, D., Pyle, L., Ly, T., Messer, L., Clinton, P., Westfall, E., Wadwa, R. P., & Buckingham, B.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2015-08-12
- Volume
- 38
- Issue
- 10
- Pages
- e158-e159
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W1171229282
- Cited by
- 102
- References
- 0
- FWCI
- 8.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Acetaminophen on CGM Glucose in an Outpatient Setting. https://app.cochat.ai/papers/10.2337/dc15-1096
- The paper
- Maahs, D. M., DeSalvo, D., Pyle, L., Ly, T., Messer, L., Clinton, P., Westfall, E., Wadwa, R. P., & Buckingham, B. (2015). Effect of Acetaminophen on CGM Glucose in an Outpatient Setting. Diabetes Care. https://doi.org/10.2337/dc15-1096
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.