Sustained Efficacy of Insulin Pump Therapy in Type 2 Diabetes: 9-Year Follow-up in a Cohort of 161 Patients
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Continuous subcutaneous insulin infusion (CSII) is a valuable option for patients with type 2 diabetes in whom glycemic targets are not met despite multiple daily injections (MDIs) at high insulin doses, as recently demonstrated in the multicenter randomized OpT2mise trial (1). However, data on the durability of glucose control with CSII are lacking (1,2). We report here the long-term efficacy of CSII in a cohort of 161 patients (51% female) with type 2 diabetes who started pump therapy between 1998 and 2012. The patients’ mean age was 58.3 ± 9.8 years, and mean BMI was 33.2 ± 6.6 kg/m2. The mean duration of diabetes was 15 ± 8.1 years, and mean glycated hemoglobin (HbA1c) was 9.0 ± 1.7% (74 ± 18.6 mmol/mol). At baseline, 96% of patients were receiving insulin: 48% were receiving basal-bolus regimens, 37% were receiving premixed …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reznik, Y., Cohen, O., Aronson, R., Conget, I., Runzis, S., Castaneda, J., & Lee, S. W. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61037-0 · Cited by 233
Self-citation
Cited by
Forlenza, G. P., Carlson, A. L., Galindo, R. J., Kruger, D. F., Levy, C. J., McGill, J. B., Umpierrez, G., & Aleppo, G. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0206 · Cited by 70
“05).(29) Very recently, a retrospective observational study of 3952 T2D participants using a tubeless insulin pump showed a reported reduction in mean HbA1c by -1.”
BackgroundSocio-Economic Inequity: Diabetes in New Zealand
Holder-Pearson, L., & Chase, J. G. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.756223 · Cited by 38
Reznik, Y., Carvalho, M., Fendri, S., Prevost, G., Chaillous, L., Riveline, J. P., Hanaire, H., Dubois, S., Houéto, P., Pasche, H., et al. (2024) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15351 · Cited by 34
“23 Nevertheless, a large proportion of people using an insulin pump do not reach their glycaemic target, as shown in the OPT2MISE trial where 40% of participants still had an HbA1c level >8% (64 mmol/ mol) at study end.”
BackgroundSelf-citationJendle, J., & Reznik, Y. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15087 · Cited by 26
Self-citationCarlson, A. L., Huyett, L. M., Jantz, J., Chang, A., Vienneau, T., & Ly, T. T. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108735 · Cited by 20
Metadata
- Authors
- Morera, J., Joubert, M., Morello, R., Rod, A., Lireux, B., & Reznik, Y.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2016-02-28
- Volume
- 39
- Issue
- 6
- Pages
- e74-e75
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2325301227
- Cited by
- 20
- References
- 1
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.