Day-and-Night Closed-Loop Control Using the Unified Safety System in Adolescents With Type 1 Diabetes at Camp
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Adolescence marks a challenging time in diabetes care (1). Automated insulin delivery has the potential to overcome some of the barriers, such as missed meal boluses and nocturnal hypoglycemia. The University of Virginia Unified Safety System (USS) is one of the most tested control-to-range approaches and operates on an Android-based system that uses a Dexcom G4 PLATINUM Share glucose sensor and Roche Accu-Chek pump (2). The objective of this study was to test the efficacy of USS in day-and-night closed-loop control (CLC) in adolescents with type 1 diabetes at camp, where large meals and physical activity challenge glucose control. In this study, eligible subjects with type 1 diabetes on pump therapy were randomized to either CLC ( n = 17) or sensor-augmented pump (SAP) ( n = 16) for 5 days. There was no A1C restriction. Clinical characteristics of the 33 subjects include mean ± SD (min–max) age of 17.9 ± 5.5 years (10.1–35.0), weight 68 ± 17 kg (37.3–104.3), A1C …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Cited by
A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes
Breton, M. D., Kanapka, L. G., Beck, R. W., Ekhlaspour, L., Forlenza, G. P., Cengiz, E., Schoelwer, M., Ruedy, K. J., Jost, E., Carria, L., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2004736 · Cited by 455
Self-citationBekiari, E., Kitsios, K., Thabit, H., Tauschmann, M., Athanasiadou, E., Karagiannis, T., Haidich, A.-B., Hovorka, R., & Tsapas, A. (2018) · BMJ · doi:10.1136/bmj.k1310 · Cited by 437
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Breton, M. D., Cherñavvsky, D. R., Forlenza, G. P., DeBoer, M. D., Robic, J., Wadwa, R. P., Messer, L. H., Kovatchev, B. P., & Maahs, D. M. (2017) · Diabetes Care · doi:10.2337/dc17-0883 · Cited by 179
“Using the DiAs system developed at the University of Virginia (UVA), we have conducted clinical trials in summer and winter camp settings where PA was typically much greater than during daily life for adolescents and young adults (13,20).”
MethodSelf-citationIsganaitis, E., Raghinaru, D., Ambler-Osborn, L., Pinsker, J. E., Buckingham, B. A., Wadwa, R. P., Ekhlaspour, L., Kudva, Y. C., Levy, C. J., Forlenza, G. P., et al. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0572 · Cited by 115
Self-citation
Metadata
- Authors
- Ly, T. T., Buckingham, B. A., DeSalvo, D. J., Shanmugham, S., Satin-Smith, M., DeBoer, M. D., Oliveri, M. C., Schertz, E., Breton, M. D., & Cherñavvsky, D. R.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2016-06-06
- Volume
- 39
- Issue
- 8
- Pages
- e106-e107
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2408906155
- Cited by
- 41
- References
- 1
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.