CoChat

Performance of the Insulin-Only iLet Bionic Pancreas and the Bihormonal iLet Using Dasiglucagon in Adults With Type 1 Diabetes in a Home-Use Setting

Open access
Castellanos, Luz E., Balliro, Courtney A., Sherwood, Jordan S., Jafri, Rabab, Hillard, Mallory A., Greaux, Evelyn, Selagamsetty, Rajendranath, Zheng, Hui, El-Khatib, Firas H., Damiano, Edward R., Russell, Steven J. · 2021 · Diabetes Care
Cited by 74

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Reductions in blood glucose levels in people with diabetes are often achieved at the expense of increased hypoglycemia. A novel approach is to automatically deliver microdose glucagon when automation of insulin delivery alone is not sufficient to prevent hypoglycemia. The approach requires a bihormonal device and a stable form of glucagon or glucagon analog. The iLet bionic pancreas (Beta Bionics, Inc.) is a purpose-built, fully integrated device that receives a signal from a continuous glucose monitor (CGM) and contains autonomous, lifelong learning, mathematical dosing algorithms, which are initialized only with the patient’s body weight (1). We evaluated the function and safety of the iLet in both its insulin-only configuration and its bihormonal configuration delivering dasiglucagon, a chemically stable glucagon analog (Zealand Pharma), in a home-use study in adults with type 1 diabetes (T1D). This open-label, random-order, crossover, home-use trial (clinical trial reg. no. NCT03840278, ClinicalTrials.gov) was the first human study to test the bihormonal iLet configuration and the first multiday use of dasiglucagon in people with T1D (2). Ten participants used the insulin-only iLet for 7 days with insulin lispro (Eli Lilly) or aspart (Novo Nordisk), the bihormonal iLet for 7 days with dasiglucagon (4 mg/mL) and insulin lispro or aspart, or both, using the same glucose target (110 mg/dL), in random order. There were no restrictions on diet or exercise. The primary outcomes were prespecified iLet operational thresholds. The key secondary outcome was the median time with CGM glucose <54 mg/dL on days 2–7 (after one day of adaptation). All participants completed the study. …

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc20-1086

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Castellanos, L. E., Balliro, C. A., Sherwood, J. S., Jafri, R., Hillard, M. A., Greaux, E., Selagamsetty, R., Zheng, H., El-Khatib, F. H., Damiano, E. R., & Russell, S. J.
Venue
Diabetes Care
Published
2021-06-01
Volume
44
Issue
6
Pages
e118-e120
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W3157605032
Cited by
74
References
2
FWCI
8.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.