Cited by 52Diabetes Management and ResearchDiabetes Management and EducationDiabetes and associated disorders

Advanced Closed-Loop Control System Improves Postprandial Glycemic Control Compared With a Hybrid Closed-Loop System Following Unannounced Meal

Garcia-Tirado, Jose, Diaz, Jenny L., Esquivel-Zuniga, Rebeca, Koravi, Chaitanya L.K., Corbett, John P., Dawson, Martha, Wakeman, Christian, Barnett, Charlotte L. +5 more·2021·Diabetes Care

Published version of a preprint

Abstract

Objective Meals are a major hurdle to glycemic control in type 1 diabetes (T1D). Our objective was to test a fully automated closed-loop control (CLC) system in the absence of announcement of carbohydrate ingestion among adolescents with T1D, who are known to commonly omit meal announcement. Research design and methods Eighteen adolescents with T1D (age 15.6 ± 1.7 years; HbA1c 7.4 ± 1.5%; 9 females/9 males) participated in a randomized crossover clinical trial comparing our legacy hybrid CLC system (Unified Safety System Virginia [USS]-Virginia) with a novel fully automated CLC system (RocketAP) during two 46-h supervised admissions (each with one announced and one unannounced dinner), following 2 weeks of data collection. Primary outcome was the percentage time-in-range 70-180 mg/dL (TIR) following the unannounced meal, with secondary outcomes related to additional continuous glucose monitoring-based metrics. Results Both TIR and time-in-tight-range 70-140 mg/dL (TTR) were significantly higher using RocketAP than using USS-Virginia during the 6 h following the unannounced meal (83% [interquartile range 64-93] vs. 53% [40-71]; P = 0.004 and 49% [41-59] vs. 27% [22-36]; P = 0.002, respectively), primarily driven by reduced time-above-range (TAR >180 mg/dL: 17% [1.3-34] vs. 47% [28-60]), with no increase in time-below-range (TBR Conclusions A new fully automated CLC system with automatic prandial dosing was proven to be safe and feasible and outperformed our legacy USS-Virginia…

Integrity signals

Registry

Crossref · 10.2337/dc21-0932

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A fully automated AID system equipped with a meal detection algorithm is considered the ultimate solution to addressing the missed meal insulin boluses, and investigational systems have already shown substantial progress in this field.

    “A fully automated AID system equipped with a meal detection algorithm is considered the ultimate solution to addressing the missed meal insulin boluses, and investigational systems have already shown substantial progress in this field.107”

    From The future of type 1 diabetes therapy (2025) · cites this paper as [107]

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 33 · Cited by 52

Authors
Garcia-Tirado, J., Diaz, J. L., Esquivel-Zuniga, R., Koravi, C. L. K., Corbett, J. P., Dawson, M., Wakeman, C., Barnett, C. L., Oliveri, M. C., Myers, H., Krauthause, K., Breton, M. D., & DeBoer, M. D.
Affiliations
  • Center for Diabetes Technology, University of Virginia, Charlottesville, VA
  • University of Virginia (US)
Corresponding author
DeBoer, Mark D.
Venue
Diabetes Care
Published
2021-08-16
Volume
44
Issue
10
Pages
2379-2387
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W3195008427
Cited by
52
References
33
Citations by year
2026: 7 · 2025: 13 · 2024: 7 · 2023: 14 · 2022: 11
FWCI
5.98
Type
journal article
Language
en
Open access
closed
Locations
  • Diabetes Care (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
Keywords
type 1 diabetes, feedback control, hybrid closed-loop system, postprandial glucose control, adolescents, time in range, time above range, time below range, insulin delivery, continuous glucose monitoring, hypoglycemia, hyperglycemia

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review