Safety and Glycemic Outcomes With a Tubeless Automated Insulin Delivery System in Very Young Children With Type 1 Diabetes: A Single-Arm Multicenter Clinical Trial
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Very young children with type 1 diabetes often struggle to achieve glycemic targets, putting them at risk for long-term complications and creating an immense management burden for caregivers. We conducted the first evaluation of the Omnipod 5 Automated Insulin Delivery System in this population. RESEARCH DESIGN AND METHODS: A total of 80 children aged 2.0–5.9 years used the investigational system in a single-arm study for 13 weeks following 14 days of baseline data collection with their usual therapy. RESULTS: There were no episodes of severe hypoglycemia or diabetic ketoacidosis. By study end, HbA1c decreased by 0.55% (6.0 mmol/mol) (P < 0.0001). Time with sensor glucose levels in target range 70–180 mg/dL increased by 10.9%, or 2.6 h/day (P < 0.0001), while time with levels <70 mg/dL declined by median 0.27% (P = 0.0204). CONCLUSIONS: Use of the automated insulin delivery system was safe, and participants experienced improved glycemic measures and reduced hypoglycemia during the study phase compared with baseline.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237 · cited 1×
“5-fold, while more than four in five achieved the less stringent >60% TIR goal (14).”
BackgroundSelf-citationState of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018
Foster, N. C., Beck, R. W., Miller, K. M., Clements, M. A., Rickels, M. R., DiMeglio, L. A., Maahs, D. M., Tamborlane, W. V., Bergenstal, R., Smith, E., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0384 · Cited by 1,907
Rawshani, A., Sattar, N., Franzén, S., Rawshani, A., Hattersley, A. T., Svensson, A.-M., Eliasson, B., & Gudbjörnsdottir, S. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31506-x · Cited by 802 · cited 1×
“health (4,5), but also on the entire family (6).”
BackgroundA Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes
Breton, M. D., Kanapka, L. G., Beck, R. W., Ekhlaspour, L., Forlenza, G. P., Cengiz, E., Schoelwer, M., Ruedy, K. J., Jost, E., Carria, L., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2004736 · Cited by 455
Self-citationTauschmann, M., Thabit, H., Bally, L., Allen, J. M., Hartnell, S., Wilinska, M. E., Ruan, Y., Sibayan, J., Kollman, C., Cheng, P., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31947-0 · Cited by 440
Self-citationBrown, S. A., Forlenza, G. P., Bode, B. W., Pinsker, J. E., Levy, C. J., Criego, A. B., Hansen, D. W., Hirsch, I. B., Carlson, A. L., Bergenstal, R. M., et al. (2021) · Diabetes Care · doi:10.2337/dc21-0172 · Cited by 286
Self-citation13. Children and Adolescents: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s013 · Cited by 223
Managing diabetes in preschool children
Sundberg, F., Barnard, K., Cato, A., de Beaufort, C., DiMeglio, L. A., Dooley, G., Hershey, T., Hitchcock, J., Jain, V., Weissberg-Benchell, J., et al. (2017) · Pediatric Diabetes · doi:10.1111/pedi.12554 · Cited by 91
Cited by
Phillip, M., Nimri, R., Bergenstal, R. M., Barnard-Kelly, K., Danne, T., Hovorka, R., Kovatchev, B. P., Messer, L. H., Parkin, C. G., Ambler-Osborn, L., et al. (2023) · Endocrine Reviews · doi:10.1210/endrev/bnac022 · Cited by 443
Self-citationTrial of Hybrid Closed-Loop Control in Young Children with Type 1 Diabetes
Wadwa, R. P., Reed, Z. W., Buckingham, B. A., DeBoer, M. D., Ekhlaspour, L., Forlenza, G. P., Schoelwer, M., Lum, J., Kollman, C., Beck, R. W., et al. (2023) · New England Journal of Medicine · doi:10.1056/nejmoa2210834 · Cited by 191
Self-citation14. Children and Adolescents: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s014 · Cited by 173
Self-citationISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery
Sherr, J. L., Schoelwer, M., Dos Santos, T. J., Reddy, L., Biester, T., Galderisi, A., van Dyk, J. C., Hilliard, M. E., Berget, C., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13421 · Cited by 152
Self-citationA Systematic Review of Commercial Hybrid Closed-Loop Automated Insulin Delivery Systems
Peacock, S., Frizelle, I., & Hussain, S. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01394-5 · Cited by 122
Forlenza, G. P., DeSalvo, D. J., Aleppo, G., Wilmot, E. G., Berget, C., Huyett, L. M., Hadjiyianni, I., Méndez, J. J., Conroy, L. R., Ly, T. T., et al. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0578 · Cited by 99
“CGM, continuous glucose monitor; GMI, glucose management indicator; IQR, interquartile range; SD, standard deviation. lower Omnipod 5 glucose targets, 33,34 and is consistent with reports of other AID systems that demonstrate higher TIR with use of lower glucose target settings.”
InfluentialSelf-citationReal-world evidence of automated insulin delivery system use
Considine, E. G., & Sherr, J. L. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0442 · Cited by 59
Self-citationPemberton, J. S., Wilmot, E. G., Barnard‐Kelly, K., Leelarathna, L., Oliver, N., Randell, T., Taplin, C. E., Choudhary, P., & Adolfsson, P. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.14962 · Cited by 44
“Most recently, the Omnipod 5 using the Dexcom G6TM has been granted Class II QJI approval as an interoperable automated glycaemic controller from ≥2 years,(77) following its acceptance by the CDRH as substantially equivalent to the t-slim X2TM with Control IQTM with proven glycaemic outcomes and safety.(78,79) The nov…”
Method
Metadata
- Authors
- Sherr, J. L., Bode, B. W., Forlenza, G. P., Laffel, L. M., Schoelwer, M. J., Buckingham, B. A., Criego, A. B., DeSalvo, D. J., MacLeish, S. A., Hansen, D. W., Ly, T. T., for the Omnipod 5 in Preschoolers Study Group:, Sherr, J. L., Weyman, K., Tichy, E., VanName, M., Brei, M., Zgorski, M., Steffen, A., Carria, L., Bode, B. W., Busby, A., Forlenza, G. P., Wadwa, R. P., Slover, R., Cobry, E., Messer, L., Laffel, L. M., Isganaitis, E., Ambler-Osborn, L., Freiner, E., Turcotte, C., Volkening, L., Schoelwer, M., Brown, S. A., Krauthause, K., Emory, E., Oliveri, M., Buckingham, B. A., Ekhlaspour, L., Kingman, R., Criego, A. B., Schwartz, B. L., Gandrud, L. M., Grieme, A., Hyatt, J., DeSalvo, D. J., McKay, S., DeLaO, K., Villegas, C., MacLeish, S. A., Wood, J. R., Kaminski, B. A., Casey, T., Campbell, W., Behm, K., Adams, R., Hansen, D. W., Stone, S. L., Bzdick, S., Bulger, J., Agostini, L., Doolittle, S., Kivilaid, K., Kleve, K., Ly, T. T., Dumais, B., Vienneau, T., Huyett, L. M., Lee, J. B., O’Connor, J., & Benjamin, E.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2022-07-26
- Volume
- 45
- Issue
- 8
- Pages
- 1907-1910
- ISSN
- 0149-5992 (ISSN-L)
- OpenAlex
- W4281713367
- Cited by
- 97
- References
- 8
- FWCI
- 11.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.