The DOI matches its Crossref record.
Determination of the Glycosylated Hemoglobins (Hb AI) with a New Microcolumn Procedure: Suitability of the Technique for Assessing the Clinical Management of Diabetes Mellitus
Abstract
Fifty-seven children who attended a diabetes camp were divided into five groups on the basis of retrospective evaluation of the management of their diabetes mellitus over the previous three or more months. Shortly after their arrival at camp, fasting blood samples were obtained for the measurement of glucose and the quantitation of Hb AI and for hemoglobin typing. Samples were obtained from 12 normal (nondiabetic) camp personnel at the same time. The Hb AI components were measured by the “macrocolumn” procedure of Trivelli et al., by the colorimetric procedure of Flukinger and Winterhalter, and by a new microcolumn procedure employing columns and reagents provided by Isolab, Inc. As might be expected from a number of previous reports by other investigators, there was no significant correlation of the percentage of Hb AI with single fasting blood sugar values. Hb AI tended to decrease as the management of diabetes became more adequate according to clinical ratings. Comparison of the Hb AI (Hb AIa+b+c) determinations showed an acceptable correlation of percentages obtained by the relatively laborious macrocolumn procedure and the more facile microcolumn procedure, indicating that the latter would be clinically useful. Values of Hb AIc obtained by the colorimetric procedure, which has been proposed as a procedure suitable for the clinical laboratory, did not correlate well with Hb AIc values determined by the macrocolumn technique, nor did these show as good an inverse relationship to the ratings of the management of diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A new colorimetric method for the estimation of glycosylated hemoglobin
Sudhakar Nayak, S., & Pattabiraman, T. N. (1981) · Clinica Chimica Acta · doi:10.1016/0009-8981(81)90312-0 · Cited by 334
A Modified Quality-of-Life Measure for Youths: Psychometric Properties
Ingersoll, G. M., & Marrero, D. G. (1991) · The Diabetes Educator · doi:10.1177/014572179101700219 · Cited by 324
Rizza, R. A., Gerich, J. E., Haymond, M. W., Westland, R. E., Hall, L. D., Clemens, A. H., & Service, F. J. (1980) · New England Journal of Medicine · doi:10.1056/nejm198012043032301 · Cited by 279
M�hlhauser, I., J�rgens, V., Berger, M., Graninger, W., G�rtler, W., Hornke, L., Kunz, A., Schernthaner, G., Scholz, V., & Voss, H. E. (1983) · Diabetologia · doi:10.1007/bf00284453 · Cited by 269
Metadata
- Authors
- Abraham, E. C., Huff, T. A., Cope, N. D., Wilson, J. B., Bransome, E. D., & Huisman, T. H. J.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1978-09-01
- Volume
- 27
- Issue
- 9
- Pages
- 931-937
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2096609805
- Cited by
- 222
- References
- 0
- FWCI
- 14.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of the Glycosylated Hemoglobins (Hb AI) with a New Microcolumn Procedure: Suitability of the Technique for Assessing the Clinical Management of Diabetes Mellitus. https://app.cochat.ai/papers/10.2337/diab.27.9.931
- The paper
- Abraham, E. C., Huff, T. A., Cope, N. D., Wilson, J. B., Bransome, E. D., & Huisman, T. H. J. (1978). Determination of the Glycosylated Hemoglobins (Hb AI) with a New Microcolumn Procedure: Suitability of the Technique for Assessing the Clinical Management of Diabetes Mellitus. Diabetes. https://doi.org/10.2337/diab.27.9.931
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.