Enhanced Glucose Utilization During Prolonged Glucose Clamp Studies
The DOI matches its Crossref record.
Abstract
Glucose clamp studies were performed to see if glucose utilization increased during extended periods of moderate hyperinsulinemia (80–100 μu/ml). Modifications of the standard euglycemic clamp were performed, and the amount of glucose metabolized (M) and the metabolic clearance rate (MCR) of glucose were calculated for each 10-min interval during the study. In seven subjects, the clamp was performed for 180 min, with the glucose infusion rate fixed from 120 to 180 min at the rate necessary to maintain basal plasma glucose concentration from 80 to 120 min. Under these conditions, mean plasma glucose concentration fell 18% during the last 60 min of the study, indicating increased glucose utilization. Twenty-four subjects, nonobese and obese normals and type II diabetics, had 3-h clamp studies performed. We documented an average increase of M by 21% and MCR by 28% in the third hour as compared with the second hour. Five-hour clamp studies in nine subjects and 8-h studies in two subjects indicated a continued rise in glucose MCR, until a plateau was reached at 4–6 h after initiation of hyperinsulinemia (mean = 88 μU/ml). This plateau was approximately 85% above the MCR of the last 30 min of a standard glucose clamp. Measurement of glucose turnover with 3H-3-glucose suggested that increasing suppression of hepatic glucose production was not responsible for the increases in glucose utilization noted. Insulin binding to erythrocytes was determined in 13 subjects before and after 180 min of hyperinsulinemia, and showed decreased total specific insulin binding. In a two-component high- and low-affinity model of insulin binding, the observed decrease in total insulin binding was primarily caused by a decrease in the high-affinity receptor component. These results suggested that glucose utilization continuously increased during a 5-h period of constant hyperinsulinemia, and this was due possibly to enhanced insulin sensitivity. This change took place in spite of a concomitant decrease in number of insulin receptors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DeFronzo, R. A., Gunnarsson, R., Björkman, O., Olsson, M., & Wahren, J. (1985) · Journal of Clinical Investigation · doi:10.1172/jci111938 · Cited by 1,167
Laakso, M., Edelman, S. V., Brechtel, G., & Baron, A. D. (1990) · Journal of Clinical Investigation · doi:10.1172/jci114644 · Cited by 930
Schwartz, N. S., Clutter, W. E., Shah, S. D., & Cryer, P. E. (1987) · Journal of Clinical Investigation · doi:10.1172/jci112884 · Cited by 394
Insulin transport across capillaries is rate limiting for insulin action in dogs.
Yang, Y. J., Hope, I. D., Ader, M., & Bergman, R. N. (1989) · Journal of Clinical Investigation · doi:10.1172/jci114339 · Cited by 303
Production of insulin resistance by hyperinsulinaemia in man
Rizza, R. A., Mandarino, L. J., Genest, J., Baker, B. A., & Gerich, J. E. (1985) · Diabetologia · doi:10.1007/bf00279918 · Cited by 293
Metadata
- Authors
- Doberne, L., Greenfield, M. S., Schulz, B., & Reaven, G. M.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1981-10-01
- Volume
- 30
- Issue
- 10
- Pages
- 829-835
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2162220798
- Cited by
- 120
- References
- 0
- FWCI
- 13.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced Glucose Utilization During Prolonged Glucose Clamp Studies. https://app.cochat.ai/papers/10.2337/diab.30.10.829
- The paper
- Doberne, L., Greenfield, M. S., Schulz, B., & Reaven, G. M. (1981). Enhanced Glucose Utilization During Prolonged Glucose Clamp Studies. Diabetes. https://doi.org/10.2337/diab.30.10.829
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.