Quantitation of Glycosylated Hemoglobin by Boronate Affinity Chromatography
Abstract
Total hemoglobin glycosylation and the contribution of glycosylation at the N-terminus of the beta-chains and at "non"-beta-N-terminal positions were quantitated by use of boronate affinity and ion exchange chromatography. Glycohemoglobin (y) was found to correlate linearly (y = 1.92x + 0.53; r = 0.96) with HbA1c (x) and to contain approximately 50% beta-N-terminally glycosylated hemoglobin. This result is in agreement with the binding on boronate agarose of the various hemoglobin components resolved by cation exchange chromatography. An amount of glycohemoglobin similar to that of HbA1c was isolatable from HbA. A slope of less than 2 results because HbA1c is retained only to 93% and the intercept of the regression line reflects the partial adherence (65%) of HbA1a + b to the resin. These results confirm the occurrence of significant "non"-beta-N-terminal glycosylation and show that under optimal chromatographic conditions total glycohemoglobin can be determined with boronate affinity chromatography.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Boronate affinity chromatography is generally robust and less affected by hemoglobin variants, but its broader detection scope theoretically includes multiple glycated species beyond the IFCC-defined β-N-terminal glycation.
“Although this method is generally robust and less affected by hemoglobin variants, its broader detection scope theoretically includes multiple glycated species beyond the IFCC-defined β-N-terminal glycation (38,39).”
From Comparison of point‑of‑care HbA1c devices with laboratory HPLC methods: A systematic review and meta‑analysis (2026) · cites this paper as [38]
Boronate affinity chromatography targets cis-diol structures of glycated residues, regardless of glycation site.
“Boronate affinity chromatography, employed by devices such as Afinion and A1C EZ 2.0, targets cis-diol structures of glycated residues, regardless of glycation site (38).”
From Comparison of point‑of‑care HbA1c devices with laboratory HPLC methods: A systematic review and meta‑analysis (2026) · cites this paper as [38]
Cited by
Sorted by citations
Carnethon, M. R. (2005) · JAMA · doi:10.1001/jama.294.23.2981 · Cited by 417 · see citing works
Berg, A. H., & Sacks, D. B. (2008) · Journal of Clinical Pathology · doi:10.1136/jcp.2007.049205 · Cited by 41 · see citing works
Wei, Y., Gu, M., Ren, Y., & Hu, Z. (2026) · Biomedical Reports · doi:10.3892/br.2026.2120 · Cited by 3 · see citing works
“N‑terminal glycation (38,39).”
Influential
- Authors
- Flückiger, R., Woodtli, T., & Berger, W.
- Affiliations
- University Hospital of Basel (CH)
- ORCID
- Flückiger, Rudolf
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1984-01-01
- Volume
- 33
- Issue
- 1
- Pages
- 73-76
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2153929626
- Cited by
- 87
- References
- 0
- Citations by year
- 2025: 2 · 2023: 2 · 2022: 4 · 2021: 1 · 2020: 3 · 2019: 3 · 2018: 3 · 2017: 3 · 2016: 3 · 2015: 4 · 2014: 2 · 2013: 6 · 2012: 3
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Diabetes (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Advanced Glycation End Products research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Genetics › Hemoglobinopathies and Related Disorders
- Keywords
- HbA1c, boronate affinity chromatography, hemoglobin A, ion-exchange chromatography
- MeSH terms
- Borohydrides, Chromatography, Affinity, Chromatography, Ion Exchange, Glycated Hemoglobin
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review