Greater Efficacy of Pulsatile Insulin in Type I Diabetics Critically Depends on Plasma Glucagon Levels
The DOI matches its Crossref record.
Abstract
The aim of this study was to investigate the role of plasma glucagon levels on the blood glucose response to intravenous insulin administered continuously or in a pulsatile manner. Six type I diabetic patients proven to have no residual insulin secretion were investigated. Endogenous glucagon secretion was inhibited by a continuous intravenous infusion of somatostatin (100 μg/h) and replaced by exogenous infusions of the hormone at three different rates (7.5, 4.5, and 2.5 μg/h), resulting in three different plasma glucagon steady-state levels (i.e., ≃200, ≃130, and ≃75 pg/ml, respectively). Each subject, in random order and on different days, was infused intravenously with regular human insulin either continuously (0.17 mU · kg−1 · min−1) or with the same amount of insulin infused in a pulsatile manner (0.85 mU · kg−1 · min−1 during 2 min followed by 8 min during which no insulin was infused). At plasma glucagon levels ≃200 pg/ml, blood glucose rose from ∼10 to ∼13 mM without any difference between the two modalities of insulin infusion. For plasma glucagon levels ≃130 pg/ml, plasma glucose remained steady throughout the experiments, but during the last 40 min, plasma glucose levels were significantly lower when insulin was administered intermittently. This greater blood glucose-lowering effect of pulsatile insulin occurred earlier and was more pronounced for plasma glucagon levels averaging 75 pg/ml. We conclude that the greater hypoglycemic effect of insulin administered intravenously in a pulsatile manner in type I diabetics critically depends on plasma glucagon circulating levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Insulin Resistance and Hyperinsulinemia
Shanik, M. H., Xu, Y., Škrha, J., Dankner, R., Zick, Y., & Roth, J. (2008) · Diabetes Care · doi:10.2337/dc08-s264 · Cited by 791
Impaired Pulsatile Secretion of Insulin in Relatives of Patients with Non-Insulin-Dependent Diabetes
O'Rahilly, S., Turner, R. C., & Matthews, D. R. (1988) · New England Journal of Medicine · doi:10.1056/nejm198805123181902 · Cited by 540
Pulsatile Insulin Secretion: Detection, Regulation, and Role in Diabetes
Pørksen, N., Hollingdal, M., Juhl, C., Butler, P., Veldhuis, J. D., & Schmitz, O. (2002) · Diabetes · doi:10.2337/diabetes.51.2007.s245 · Cited by 223
Control Mechanisms of the Oscillations of Insulin Secretion In Vitro and In Vivo
Gilon, P., Ravier, M. A., Jonas, J.-C., & Henquin, J.-C. (2002) · Diabetes · doi:10.2337/diabetes.51.2007.s144 · Cited by 168
Metadata
- Authors
- Paolisso, G., Sgambato, S., Passariello, N., Scheen, A., D'Onofrio, F., & Lefébvre, P. J.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1987-05-01
- Volume
- 36
- Issue
- 5
- Pages
- 566-570
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2028335188
- Cited by
- 35
- References
- 0
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.