CoChat

Stable-Label Intravenous Glucose Tolerance Test Minimal Model

Avogaro, Angelo, Bristow, James D, Bier, Dennis M, Cobelli, Claudio, Toffolo, Gianna · 1989 · Diabetes
Cited by 100

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The minimal model approach to estimating insulin sensitivity (SI) and glucose effectiveness in promoting its own disposition at basal insulin (SG) is a powerful tool that has been underutilized given its potential applications. In part, this has been due to its inability to separate insulin and glucose effects on peripheral uptake from their effects on hepatic glucose inflow. Prior enhancements, with radiotracer labeling of the dosage, permit this separation but are unsuitable for use in pregnancy and childhood. In this study, we labeled the intravenous glucose tolerance test (IVGTT) dosage with [6,6-2H2]glucose, [2-2H]glucose, or both stable isotopically labeled glucose tracers and modeled glucose kinetics in six postabsorptive, nonobese adults. As previously found with the radiotracer model, the tracer-estimated derived from the stable-label IVGTT was greater than SI in each case except one, and the tracer-estimated was less than SG in each instance. More importantly, however, the stable-label IVGTT estimated each parameter with an average precision of ± 5% (range 3–9%) compared to average precisions of ±74% (range 7–309%) for SGand ±22% (range 3–72%) for SI. In addition, because of the different metabolic fates of the two deuterated tracers, there were minor differences in basal insulin-derived measures of glucose effectiveness, but these differences were negligible for parameters describing insulin-stimulated processes. In conclusion, the stable-label IVGTT is a simple, highly precise means of assessing insulin sensitivity and glucose effectiveness at basal insulin that can be used to measure these parameters in individuals of all ages, including children and pregnant women.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diab.38.8.1048

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Quantitative estimation of insulin sensitivity.

    Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874 · cited 4×

    “Development of the minimal model represented an innovative approach to the estimation of S, and SG in a noninvasive fashion compared with available alternatives (9-11).”
    MethodInfluentialSelf-citation

Cited by

See all 100

Metadata

Authors
Avogaro, A., Bristow, J. D., Bier, D. M., Cobelli, C., & Toffolo, G.
Venue
Diabetes
Published
1989-08-01
Volume
38
Issue
8
Pages
1048-1055
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W1979223224
Cited by
100
References
1
FWCI
4.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.