CoChat

A Rapid and Sensitive Radioimmunoassay for the Measurement of Proinsulin in Human Serum

Bowsher, Ronald R, Wolny, James D, Frank, Bruce H · 1992 · Diabetes
Cited by 53

The DOI matches its Crossref record.

Abstract

RIA methodology is used widely to measure proinsulin in human serum. However, some RIAs lack the sensitivity necessary to quantify proinsulin in unextracted serum and require long incubation periods. We developed an RIA with a sensitivity of 3.5 in <48 h. This was accomplished by using a nonequilibrium binding reaction at room temperature and PEG-assisted second antibody precipitation as the method for separating bound and free proinsulin. We obtained a specific antiproinsulin antibody by adsorbing the initial goat antiserum with human C-peptide–agarose. Proinsulin produced 50% displacement of tracer at 25.6 pM, whereas both human insulin and C-peptide failed to displace tracer at concentrations as high as 1 μM. We evaluated several cleaved derivatives of proinsulin for cross-reactivity with the antibody. B-chain–C-peptide cleaved derivatives (≤50% cross-reactivity) were more potent than A-chain–C-peptide cleaved derivatives (<5% cross-reactivity). However, all derivatives cleaved in the region from 56–60 failed to cross-react with the antiserum. These data indicate that a major antigenic determinant is present on the C-peptide region of proinsulin adjacent to the A-chain–C-peptide junction. After administration of an oral glycemic challenge, the mean fasting serum concentration of proinsulin in normal adults rose from 4.1 ± 0.28 to 23.6 ± 3.8 pM. We found a significant difference in the proinsulin concentrations in 6 adults before and after aglycemic challenge when two different antibodies were used in the RIA. Based on the antibodies different specificity for proinsulin, we concluded that B-chain-C-peptide junctional split forms of proinsulin comprise a significant portion of circulating proinsulin material after a glycemic challenge.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diab.41.9.1084

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 53

Metadata

Authors
Bowsher, R. R., Wolny, J. D., & Frank, B. H.
Venue
Diabetes
Published
1992-09-01
Volume
41
Issue
9
Pages
1084-1090
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W2063988943
Cited by
53
References
0
FWCI
3.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Rapid and Sensitive Radioimmunoassay for the Measurement of Proinsulin in Human Serum. https://app.cochat.ai/papers/10.2337/diab.41.9.1084
The paper
Bowsher, R. R., Wolny, J. D., & Frank, B. H. (1992). A Rapid and Sensitive Radioimmunoassay for the Measurement of Proinsulin in Human Serum. Diabetes. https://doi.org/10.2337/diab.41.9.1084

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.