CoChat

Repeatability of Insulin Sensitivity and Glucose Effectiveness From the Minimal Model: Implications for Study Design

Steil, Garry M, Murray, Joseph, Bergman, Richard N, Buchanan, Thomas A · 1994 · Diabetes
Cited by 85

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

To determine the repeatability of insulin sensitivity measurements generated by the minimal model, we subjected 11 normal men to 3 frequently sampled intravenous glucose tolerance tests (FSIGTs) over the course of 12 days under conditions of fixed diet and limited physical activity. FSIGTs were analyzed by the minimal model using a full, 30-sample data set, as well as a reduced, 12-sample data set that has been proposed for population studies. Minimal model insulin sensitivity index (Si) calculated from the 30-sample data set averaged 0.8 ± 0.083 × 10−4 min−1 · (pmol/1)−1 (range 0.10–1.64 × 10−4 min−1 · (pmol/I)−1 with an average interday coefficient of variation (CV) of 20.2 ± 3.2% (range 6–44%). Glucose effectiveness (SG) was slightly less repeatable, with an average interday variability of 25.1 ± 8.8%. The mean CVs for first-phase insulin secretion (20.1 ± 3.5%) and total insulin secretion (21.4 ± 3.2%) were similar to the CV for Sp Mean insulin sensitivity calculated from the 12-sample data set (0.82 ± 0.08 × 10−4 min−1 · (pmol/1)−1 was not significantly different from the mean calculated from the full data set (P = 0.37, paired Student's t test). However, the mean CV of Sx calculated from the reduced data set tended to be greater than that calculated from the full data set (27.7 ± 5.4% vs. 20.2 ± 3.2%). Power calculations using the observed variances from the full and reduced data sets indicated that the full sample protocol is preferable for small studies designed to detect small changes in Si, whereas the reduced sample protocol is appropriate for studies with large numbers of subjects or large anticipated changes in Si

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diab.43.11.1365

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Quantitative estimation of insulin sensitivity.

    Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874 · cited 2×

    “(12,13) describing glucose disappearance after an intravenous glucose challenge has been used extensively to measure insulin sensitivity in vivo; measures of insulin sensitivity obtained with the model are closely correlated with measures obtained with the glucose clamp (14).”
    BackgroundMethodSelf-citation

Show all 1 references

Cited by

See all 85

Metadata

Authors
Steil, G. M., Murray, J., Bergman, R. N., & Buchanan, T. A.
Venue
Diabetes
Published
1994-11-01
Volume
43
Issue
11
Pages
1365-1371
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W2120035516
Cited by
85
References
1
FWCI
3.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Repeatability of Insulin Sensitivity and Glucose Effectiveness From the Minimal Model: Implications for Study Design. https://app.cochat.ai/papers/10.2337/diab.43.11.1365
The paper
Steil, G. M., Murray, J., Bergman, R. N., & Buchanan, T. A. (1994). Repeatability of Insulin Sensitivity and Glucose Effectiveness From the Minimal Model: Implications for Study Design. Diabetes. https://doi.org/10.2337/diab.43.11.1365

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.